@article{63720,
  abstract     = {{The aging behavior of closed-cell polyurethane (PUR) foam, a material widely used in household refrigeration, is studied by examining the variation of cell gas composition and thermal conductivity over time. Aging is primarily driven by gas permeation, wherein the initially present cell gases carbon dioxide and cyclopentane are progressively replaced by nitrogen and oxygen from the ambient, resulting in an increased thermal conductivity and reduced insulation performance. The cell gas composition is measured over 1400 days employing gas chromatography, and the thermal conductivity of the foam is measured over 190 days. Morphological foam characteristics, such as average cell diameter, are determined via scanning electron microscopy and barrier measurements are performed to estimate the effective diffusion coefficient of oxygen. To simulate the aging process, one-dimensional and three-dimensional models are developed for both diffusive mass transfer as well as heat transfer. The present model for the thermal conductivity explicitly accounts for condensation effects, i.e. partial condensation of cyclopentane and carbon dioxide occurring at around 12°C, which significantly influences the insulation behavior of the foam. Sensitivity analyses indicate that an initial cell gas pressure of approximately 0.7 bar yields results that closely coincide with the experimental measurements, where the three-dimensional model demonstrates better accuracy. These measurements and simulations provide valuable insights for evaluating and predicting the long-term degradation of the insulation performance of PUR foams.}},
  author       = {{Schumacher, Daniel and Guevara-Carrion, Gabriela and Kasper, Tina and Paul, Andreas and Elsner, Andreas and Peters, Bettina and Wollny, Wenke and Bluemel, Marcus and Hoelscher, Heike and Brzoska-Steinhaus, Nicola and Heil, Klaus and Schleelein, Lukas and Becker, Wolfgang and Gries, Ulrich and Vrabec, Jadran}},
  issn         = {{1359-4311}},
  journal      = {{Applied Thermal Engineering}},
  keywords     = {{Polyurethane, Foam, Gas permeation, Diffusion models, Thermal conductivity, Condensation, Gas chromatography, Scanning electron microscopy}},
  publisher    = {{Elsevier BV}},
  title        = {{{Aging of polyurethane foam: Experimental analysis and modeling of cell gas composition and thermal conductivity}}},
  doi          = {{10.1016/j.applthermaleng.2026.129850}},
  volume       = {{289}},
  year         = {{2026}},
}

@inproceedings{57899,
  abstract     = {{In Haushaltskältegeräten werden in den letzten Jahren immer häufiger Vakuumisolationspaneele (VIP) eingesetzt. Hiermit ist es unter anderem möglich, dass die Geräte in die Energieeffizienzklassen A bis C klassifiziert werden können. Ein VIP besteht vereinfacht aus einer Schutzfolie, die nahezu gasdicht ist und einem Füllmaterial, welches für die Formstabilität im Vakuum zuständig ist. Aufgrund von technischen Alterungsprozessen kommt es mit der Zeit zu einem Anstieg des Innendrucks im VIP, wodurch die Wärmeleitfähigkeit des VIP steigt. Je nach Füllmaterial erfolgt dieser Alterungsprozess unterschiedlich schnell. Im Extremfall kann so ein neues Haushalts-kältegerät der Energieeffizienzklasse A nach 1 bis 3 Jahren nur noch als Klasse D bis F eingestuft werden.
Innerhalb eines Forschungsprojekts wurden Haushaltskältegeräte mit VIP thermografisch untersucht. Im Rahmen dieser Studienarbeit wurde ein Versuchsaufbau entwickelt, mit dem die zeitliche Veränderung von Wärmebrücken begutachtet werden kann und so Rückschlüsse auf den Effizienzverlust der Geräte möglich sind. Der Funkionsnachweises dieses Versuchsaufbaus wurden an einem Haushaltskältegerät mit künstlich gealterten Vakuumisolationspaneelen durchgeführt. Diese Arbeiten bieten zukünftig die Möglichkeiten Haushaltskältegeräten mit VIP bezüglich ihres Degenerationsverhaltens besser zu beurteilen.
}},
  author       = {{Potthast, Emily and Elsner, Andreas and Paul, Andreas and Kasper, Tina}},
  booktitle    = {{Deutsche Kälte- und Klimatagung 2024 Dresden}},
  keywords     = {{Haushaltskältegeräte, Energieaufnahme, Alterung, Isolierung, Vakuumisolationspaneele}},
  location     = {{Dresden}},
  publisher    = {{Deutscher Kälte‐ und Klimatechnischer Verein e.V.}},
  title        = {{{Thermografische Messungen an Haushaltskältegeräten mit Vakuumisolationspaneele}}},
  year         = {{2025}},
}

@inproceedings{57897,
  author       = {{Paul, Andreas and Elsner, Andreas and Kasper, Tina and Schumacher, Daniel and Vrabec, Jadran  and Hölscher, Heike  and Bluemel, Marcus  and Wollny, Wenke and Becker, Wolfgang and Brzoska-Steinhaus, Nicola }},
  location     = {{September}},
  title        = {{{Alterungsbedingter Anstieg der Energieaufnahme von Haushaltskältegeräten}}},
  year         = {{2024}},
}

@inproceedings{57898,
  author       = {{Kruse, Simon and Elsner, Andreas and Paul, Andreas and Kasper, Tina}},
  keywords     = {{Haushaltskältegeräte, Energieaufnahme, Alterung}},
  location     = {{Dresden}},
  title        = {{{Anstieg der Energieaufnahme von Haushaltskältegeräten}}},
  year         = {{2024}},
}

@article{43391,
  abstract     = {{The technical importance of paraffins as phase change materials (PCM) in heat storage systems increases. Knowledge on the thermal conductivity of paraffins is necessary for the design and optimization of heat storage systems. However, for most paraffins solely the thermal conductivity of the liquid state has been sufficiently investigated. For the solid state, precise thermal conductivity data are only known for a few paraffins, while only generalized values are available for the remainder, some of which contradict each other. In this study, a measurement setup based on the modified guarded hot plate method is developed. It is used to investigate the thermal conductivity of several paraffines in the solid state, including pure n-docosane and its compounds with different types and concentrations of graphite. For n-docosane in the solid state, the thermal conductivity is determined to be 0.49 W/(m K). A particle size of 200 μm with a spherical shape turns out to be optimal to increase the thermal conductivity. This allows the thermal conductivity of a compound with 10% graphite to increase by a factor of three compared to the pure paraffin. Furthermore, significant differences to thermal conductivity data from the literature are found.}},
  author       = {{Paul, Andreas and Baumhögger, Elmar and Dewerth, Mats-Ole and Hami Dindar, Iman and Sonnenrein, Gerrit and Vrabec, Jadran}},
  issn         = {{1388-6150}},
  journal      = {{Journal of Thermal Analysis and Calorimetry}},
  keywords     = {{Physical and Theoretical Chemistry, Condensed Matter Physics}},
  publisher    = {{Springer Science and Business Media LLC}},
  title        = {{{Thermal conductivity of solid paraffins and several n-docosane compounds with graphite}}},
  doi          = {{10.1007/s10973-023-12107-2}},
  year         = {{2023}},
}

@inproceedings{43394,
  abstract     = {{Die für die Berechnung des Energieeffizienzindex von Haushaltskältegeräten benötigten Parameter werden durch Norm-Messungen im Neuzustand der Geräte bestimmt. Aus früheren Untersuchungen ist bekannt, dass durch verschiedene technische Alterungsmechanismen der Energieverbrauch über eine Produktlebensdauer von 18 Jahren um bis zu 33 % zunehmen kann. Ziel des vom BMWi geförderten Projekts ALGE war es, die verschie-denen Ursachen und Einflussgrößen für die Alterung von Haushaltskältegeräten zu ermitteln und eine Alterungs-funktion zu bestimmen, die den zeitlichen Verlauf des zunehmenden Energieverbrauchs beschreibt.
In diesem Projekt wurde das Alterungsverhalten von Haushaltskältegeräten durch 100 Normenergieverbrauchs-messungen an 32 real gealterten Geräten untersucht. Aus den gewonnenen Ergebnissen konnte eine Alterungs-funktion bestimmt werden, die den Anstieg des Energieverbrauchs beschreibt. Alle untersuchten Geräte wurden an der Universität Paderborn im Neuzustand vermessen und nach einer Laufzeit von bis zu 21 Jahren erneut geprüft. Bereits nach einem zweijährigen Betrieb konnte ein Mehrverbrauch von bis zu 11 % festgestellt werden. Über die durchschnittliche Produktlebensdauer von Haushaltskältegeräten von ca. 16 Jahren steigert sich der Energieverbrauch um durchschnittlich 27 %.
Im Rahmen des Projekts wurden verschiedene Systemkomponenten, wie Isolierung und Verdichter, hinsichtlich ihres Alterungsverhaltens untersucht. Bei dem im Gehäuse als Isolierung verwendeten PUR-Schaum konnte über einen Zeitraum von 31 Monaten ein Anstieg der Wärmeleitfähigkeit von 19,5 W/(m⋅K) auf 24,5 W/(m⋅K) festge-stellt werden. Zur Untersuchung der Alterung der Verdichter wurden zuvor auf einem Kalorimeterteststand ver-messene Verdichter in Geräte eingebaut. Nach einem zweijährigen Betrieb wurden diese Verdichter wieder aus-gebaut und erneut vermessen. Hierbei konnte keine Änderung des COP festgestellt werden. Zusätzlich zu den technischen Parametern wurde der Einfluss des Verbraucherverhaltens analysiert. Hier zeigte sich, dass bis zu 33 % des Gesamtenergieverbrauchs nach einer mehrjährigen Nutzungsdauer verbraucherinduziert sein können.}},
  author       = {{Paul, Andreas and Baumhögger, Elmar and Elsner, Andreas and Reineke, Michael and Kasper, Tina and Schumacher, Daniel and Vrabec, Jadran and  Hüppe, Christian and  Stamminger, Rainer and Hölscher, Heike and Stoll, Ragnar and Wagner, Hendrik and  Gries, Ulrich and Becker, Wolfgang}},
  isbn         = {{978-3-932715-55-6}},
  keywords     = {{Haushaltskältegeräte, Energieverbrauch, Alterung, Verdichter, PUR-Schaum}},
  location     = {{Magdeburg}},
  publisher    = {{Deutscher Kälte‐ und Klimatechnischer Verein e.V.}},
  title        = {{{Alterungsmechanismen von Haushaltskältegeräten}}},
  year         = {{2023}},
}

@misc{46753,
  abstract     = {{Die Energieaufnahme von Haushaltskältegeräten ist seit den 1990er Jahren erheblich gesunken. Dieser Wert wird von den Herstellern im Neuzustand der Geräte unter Normbedingungen bestimmt. Wie jedes technische System unterliegen jedoch auch Haushaltskältegeräte einem Alterungsprozess, der zu einem Anstieg der Energieaufnahme über die Zeit führt. Im Rahmen dieser Dissertation wurde auf der Grundlage von 100 Messungen der Energieaufnahme, die an 32 Geräten über einen Zeitraum von 21 Jahren durchgeführt wurden, ein Alterungsmodell entwickelt. Dieses Modell ist das erste, das mit Hilfe von Daten der Energieaufnahme real gealterter Geräte entwickelt wurde. Es beschreibt einen Anstieg der Energieaufnahme von 27 % über die durchschnittliche Einsatzzeit eines Haushaltskältegeräts von 16 Jahren. Der stärkste Anstieg erfolgt in den ersten fünf Betriebsjahren. Durch Diffusionsvorgänge in dem im Gehäuse verbauten Polyurethan-Schaum wird das im Zellgas vorhandene Kohlenstoffdioxid durch Luft ersetzt. Hierdurch steigt die Wärmeleitfähigkeit des Schaums um ca. 33 % an, wodurch sich die Energieaufnahme der Geräte erhöht. Des Weiteren wurde der Einsatz von Paraffinen als Phasenwechselmaterial in Haushaltskältegeräten untersucht. Durch deren Einsatz konnte die Energieaufnahme gesenkt und die Funktionalität der Geräte gesteigert werden. Hierfür sind detaillierte Kenntnisse der Materialkenndaten der Paraffine notwendig. Die Wärmeleitfähigkeit der verschiedenen Paraffin-Stoffgruppen in der festen Phase ist jedoch bisher nur unzureichend untersucht worden. Daher wurde ein Messaufbau entwickelt, mit dem die Wärmeleitfähigkeit von festem Paraffin bestimmt werden kann, und es wurden entsprechende Messungen durchgeführt.}},
  author       = {{Paul, Andreas}},
  publisher    = {{LibreCat University}},
  title        = {{{Analyse von Alterungsmechanismen im Hinblick auf die Effizienz von Haushaltskältegeräten}}},
  doi          = {{10.17619/UNIPB/1-1784}},
  year         = {{2023}},
}

@article{29208,
  abstract     = {{The parameters required to calculate the energy efficiency of household refrigerating appliances (i.e. refrigerators, freezers and their combinations) are determined by standard measurements. According to regulations, these measurements are carried out when the appliances are new. It is known from previous studies that various technical aging mechanisms can increase electrical energy consumption by up to 36 % over a product lifespan of 18 years. In order to determine the time dependence of the energy consumption of household refrigerating appliances, repeated measurements are carried out in this work. Eleven new appliances are examined under standard measurement conditions. After just two years of operation, an additional energy consumption of up to 11 % is determined. Furthermore, 21 older appliances that had previously been measured in new condition are tested again after up to 21 years of operation. For these older appliances, an average increase of energy consumption of 28 % is found. For individual appliances, the maximum increase is 36 %. An aging model is developed on the basis of these measurement results, which may help to predict the aging-related increase of energy consumption of household refrigerating appliances. This model shows an average increase in energy consumption of 27 % for an appliance age of 16 years. Supplemental performance tests of eight compressors do not show any significant aging effects related to these devices after two years of operation. Furthermore, measurements of the thermal conductivity of aged polyurethane foam test samples are carried out and an increase of its thermal conductivity of 26 % over a period of about three years is determined.}},
  author       = {{Paul, Andreas and Baumhögger, Elmar and Elsner, Andreas and Reineke, Michael and Hueppe, Christian and Stamminger, Rainer and Hoelscher, Heike and Wagner, Hendrik and Gries, Ulrich and Becker, Wolfgang and Vrabec, Jadran}},
  issn         = {{1359-4311}},
  journal      = {{Applied Thermal Engineering}},
  keywords     = {{Industrial and Manufacturing Engineering, Energy Engineering and Power Technology}},
  publisher    = {{Elsevier BV}},
  title        = {{{Impact of aging on the energy efficiency of household refrigerating appliances}}},
  doi          = {{10.1016/j.applthermaleng.2021.117992}},
  volume       = {{205}},
  year         = {{2022}},
}

@article{20921,
  abstract     = {{The increase of the thermal conductivity of PUR foam in the insulation of the cabinet is an important cause for aging processes of household refrigerating appliances. To determine the influence of the PUR foam aging on energy consumption, the development of a new measurement method is necessary be- cause current methods influence the aging behavior of household refrigerators and are therefore not applicable in general. Based on a latent heat sink, constructed as an ice water bucket, a new measure- ment method is developed to determine the k ·A value over time. With this method, the k ·A value of four household refrigerating appliances was determined over an interval of 14 months. The k ·A value increased between 3.6% and 11.5% during this period.}},
  author       = {{Paul, Andreas and Baumhögger, Elmar and Elsner, Andreas and Moczarski, Lukas and Reineke, Michael and Sonnenrein, Gerrit and Hueppe, Christian and Stamminger, Rainer and Hoelscher, Heike and Wagner, Hendrik and Gries, Ulrich and Freiberger, Alfred and Becker, Wolfgang and Vrabec, Jadran}},
  issn         = {{0140-7007}},
  journal      = {{International Journal of Refrigeration}},
  pages        = {{235--242}},
  title        = {{{Determining the heat flow through the cabinet walls of household refrigerating appliances}}},
  doi          = {{10.1016/j.ijrefrig.2020.10.007}},
  year         = {{2021}},
}

@article{27290,
  abstract     = {{Domestic refrigeration appliances are standard household commodities. Although policies, such as the energy labelling, prompted technical improvements and decreased appliance energy consumption throughout recent decades, important parameters were disregarded. These refer to the efficiency loss over time and the consumer behaviour. The objective of this contribution was to develop a dynamic energy model to determine the power consumption of refrigeration appliances considering degradation factors and behaviour. These were included by model parameters for direct consumer interactions, such as the storage behaviour, door openings and temperature setting, as well as indirect actions, e.g. exposing an appliance to specific temperature conditions at an installation site. For this, an online-survey was conducted to evaluate the consumer behaviour. A total of 706 consumers participated in the national questionnaire, serving as input for the dynamic energy model. It was found that the efficiency loss increases the power consumption by at least 1% annually, leading to an excess of 10% after 10 years of usage. Another important finding was that 32.5% of appliance’s power consumption results from consumer behaviour, whereas the promotion of behavioural changes leads to a significant decrease of the consumer-induced consumption. Consequently, this study provides a tool to evaluate the impact of policies targeting refrigeration appliances, stressing that efficiency loss and behaviour should be integrated into future policy approaches.}},
  author       = {{Hueppe, Christian and Geppert, Jasmin and Moenninghoff-Juessen, Julia and Wolff, Lena and Stamminger, Rainer and Paul, Andreas and Elsner, Andreas and Vrabec, Jadran and Wagner, Hendrik and Hoelscher, Heike and Becker, Wolfgang and Gries, Ulrich and Freiberger, Alfred}},
  issn         = {{0301-4215}},
  journal      = {{Energy Policy}},
  title        = {{{Investigating the real life energy consumption of refrigeration appliances in Germany: Are present policies sufficient?}}},
  doi          = {{10.1016/j.enpol.2021.112275}},
  year         = {{2021}},
}

@article{21514,
  abstract     = {{The influence of latent heat storage elements on the cooling performance and the temperature rise time of household refrigerating appliances is studied experimentally in the context of the “new global refriger- ator standard”IEC 62552:2015. In addition to the daily energy consumption, this international standard- ization introduced performance tests for cooling capacity and temperature rise time. While the cooling capacity has long been anchored in various test procedures of consumer organizations, the temperature rise time, which has only been tested on freezers so far, will be a decisive factor in the future. Moreover, the need for so-called "smart appliances" that may balance power consumption is increasing since such devices may compensate the volatility of renewable energies and thus stabilize the power grid. Against this background, eight commercial household refrigerators and refrigerator-freezers are equipped with polymer-bound phase change materials (PCM) and their performance is determined under the new stan- dard test conditions. The results show that the introduction of PCM increases the cooling capacity by up to 33 % and also increases the temperature rise time by up to 145 %, without affecting power consump- tion, as compared to the unmodified refrigeration appliances.}},
  author       = {{Sonnenrein, Gerrit and Baumhögger, Elmar and Elsner, Andreas and Morbach, A. and Neukötter, Moritz and Paul, Andreas and Vrabec, J.}},
  issn         = {{0140-7007}},
  journal      = {{International Journal of Refrigeration}},
  pages        = {{448--456}},
  publisher    = {{Elsevier}},
  title        = {{{Improving the performance of household refrigerating appliances through the integration of phase change materials in the context of the new global refrigerator standard IEC 62552:2015}}},
  doi          = {{10.1016/j.ijrefrig.2020.07.025}},
  volume       = {{119}},
  year         = {{2020}},
}

@article{21512,
  abstract     = {{Despite the omnipresence of household refrigeration appliances, there is still a lack of knowledge about their agerelated efficiency loss over time. Past studies provide basic evidence for increasing electricity consumption of cooling appliances with ageing but fail to investigate the associated technical wear. Concentrating on the degradation of the thermal insulation, we first determined the ageing process of sealed samples of polyurethane rigid foam by investigating changes in cell gas composition and thermal conductivity over time. Simultaneously, the main challenge was to develop an approach that investigates the age-related efficiency loss of the insulation without its destruction. This testing procedure is referred to as the Bonn method. The non-destructive Bonn method was applied to varying refrigerator models in a series of successive experiments to evaluate the insulation degradation over time. Subsequently, the physical relationship between the test value of the Bonn method and the heat transfer through the multi-layered compartment walls of domestic refrigeration appliances was established, ultimately characterising the degrading insulation in terms of increasing heat transfer. Our results give substantiated evidence that the efficiency loss of cooling appliances is greatly influenced by insulation degradation over time. The ageing of sealed samples of polyurethane rigid foam indicates a large initial increase of thermal conductivity by 15% within the first year, corresponding to a change in cell gas composition. These results are in line with those of the Bonn method, emphasising an increasing heat flow through the multi-layered compartment walls of domestic refrigerators with ageing. Therewith, the present study is of significance to a wide range of stakeholders and forms the basis for future research.}},
  author       = {{Hueppe, Christian and Geppert, Jasmin and Stamminger, Rainer and Wagner, Hendrik and Hoelscher, Heike and Vrabec, Jadran and Paul, Andreas and Elsner, Andreas and Becker, Wolfgang and Gries, Ulrich and Freiberger, Alfred}},
  issn         = {{1359-4311}},
  journal      = {{Applied Thermal Engineering}},
  publisher    = {{Elsevier}},
  title        = {{{Age-related efficiency loss of household refrigeration appliances: Development of an approach to measure the degradation of insulation properties}}},
  doi          = {{10.1016/j.applthermaleng.2020.115113}},
  volume       = {{173}},
  year         = {{2020}},
}

@article{21519,
  author       = {{Grabo, Matti and Weber, Daniel and Paul, Andreas and Klaus, Tobias and Bermpohl, Wolfgang and Krauter, Stefan and Kenig, Eugeny}},
  isbn         = {{978-88-95608-73-0}},
  journal      = {{CHEMICAL ENGINEERING TRANSACTIONS}},
  pages        = {{895--900}},
  publisher    = {{AIDIC The Italian Association of Chemical Engineering}},
  title        = {{{Numerical Investigation of the Temperature Distribution in PCM-integrated Solar Modules}}},
  doi          = {{10.3303/CET1976150}},
  volume       = {{76}},
  year         = {{2019}},
}

@inproceedings{21521,
  author       = {{Grabo, Matti and Weber, Daniel and Paul, Andreas and Klaus, Tobias and Bermpohl, Wolfgang and Kenig, Eugeny}},
  location     = {{Frankfurt am Main}},
  title        = {{{Numerische Untersuchung der Temperaturverteilung in PCM-integrierten Solarmodulen}}},
  year         = {{2019}},
}

@inproceedings{21520,
  author       = {{Grabo, Matti and Weber, Daniel and Paul, Andreas and Klaus, Tobias and Bermpohl, Wolfgang and Krauter, Stefan and Kenig, Eugeny}},
  location     = {{Nordhausen}},
  title        = {{{Entwicklung eines thermischen 1D-Simulationsmodells zur Bestimmung der Temperaturverteilung in Solarmodulen}}},
  year         = {{2019}},
}

@inproceedings{21518,
  abstract     = {{Wie jedes technische System unterliegen auch Haushaltskältegeräte einer alterungsbedingten Degeneration, die zu einem Anstieg der Energieaufnahme über die Lebensdauer dieser Geräte führt. Ursache hierfür sind verschiedene Effekte, die in dem vom BMWi geförderten Projekt ALGE untersucht werden. Aus den so gewonnenen Erkenntnissen sollen dann degenerationsbeständigere Haushaltskältegeräte entwickelt werden. Eine wichtige Alterungsursache ist der Anstieg der Wärmeleitfähigkeit des PUR-Schaums der Gehäuseisolierung. Zur Bestimmung dieses Einflusses auf die Energieaufnahme ist die Entwicklung neuer Messmethoden notwendig, die zerstörungsfrei sein und den realen Anwendungsbedingungen möglichst nahekommen sollen. Dazu wurde eine Wärmesenke entwickelt, die den Geräteinnenraum unabhängig vom Kältekreislauf abkühlt. Die Wärmesenke ist als Eiswasserbehälter ausgeführt, sodass die Schmelzenthalpie des Eises die durch die Isolierung in den Geräteinnenraum einfallende Wärme aufnimmt. Durch die Bestimmung der Abtauzeit einer bestimmten Eismenge kann so der alterungsbeeinflusste 𝑘∙𝐴-Wert des Gehäuses von Haushaltskältegeräten bestimmt werden.}},
  author       = {{Paul, Andreas and Moczarski, Lukas and Gieselmann, Mirko and Reineke, Michael and Elsner, Andreas and Baumhögger, Elmar and Sonnenrein, Gerrit and Vrabec, Jadran}},
  isbn         = {{978-3-932715-52-5}},
  location     = {{Ulm}},
  publisher    = {{Deutscher Kälte- und Klimatechnischer Verein e.V. }},
  title        = {{{Bestimmung von Wärmeverlusten in Haushaltskältegeräten}}},
  year         = {{2019}},
}

@article{21516,
  abstract     = {{This study presents the results of an experimental investigation of the influence of latent
thermal heat storage elements on the power consumption as well as the temperature distribution
of commercial household refrigerators.Two evaporator types and a standard wireand-
tube condenser are equipped with copolymer-bound phase change materials (PCM) and
the performance is determined under standard conditions. The results show that refrigerating
appliances equipped with PCM can be optimized through modifications of the control
strategy to achieve different targets: (a) Power consumption can be significantly reduced
by increasing the evaporator and decreasing the condenser temperature. (b) Temperature
fluctuations in the refrigerator’s fresh-food compartment during the cooling cycle can be
reduced from 4 °C to 0.5 °C. (c) The cooling cycle duration can be tripled without compromising
the fresh-food compartment conditions. The latter may help to meet the growing
demand for balancing power consumption to stabilize the power grid, e.g. if the share of
highly fluctuating, sustainable energy supply is large.}},
  author       = {{Sonnenrein, Gerrit and Baumhögger, Elmar and Elsner, Andreas and Fieback, K. and Morbach, A. and Paul, Andreas and Vrabec, J.}},
  issn         = {{0140-7007}},
  journal      = {{International Journal of Refrigeration}},
  pages        = {{166--173}},
  title        = {{{Copolymer-bound phase change materials for household refrigerating appliances: experimental investigation of power consumption, temperature distribution and demand side management potential}}},
  doi          = {{10.1016/j.ijrefrig.2015.06.030}},
  volume       = {{60}},
  year         = {{2015}},
}

@inproceedings{21517,
  author       = {{Elsner, Andreas and Müller, Michael and Paul, Andreas and Vrabec, Jadran}},
  location     = {{Hannover}},
  publisher    = {{Deutscher Kälte- und Klimatechnischer Verein e.V. }},
  title        = {{{Zunahme des Stromverbrauchs von Haushaltskältegeräten durch Alterung}}},
  year         = {{2013}},
}