_id: '15340'
abstract:
- lang: eng
  text: 'There are a couple of acoustic systems that are well suited for continuous
    and reliable concentration measurement of liquids, but the reliability is a great
    challenge: Most systems determine the amplitude ratio of deflected ultrasound
    bursts at different boundaries as well as the sound velocity of the liquid in
    order to calculate its acoustic impedance and therewith its density. The problem
    is the sensitivity of variations of reference material properties as well as abrasion
    or soiling of the boundaries. This contribution is about a new model-based method
    that uses the whole surface of an acoustic waveguide as reference boundary. On
    the one hand the integral over a large boundary decreases influence of small boundary
    defects. On the other hand it is possible to analyze different modes of sound
    in the fluid. This redundancy can be used to increase reliability. The decomposition
    of the received signal in its modal components by means of principle component
    analysis will be discussed in detail. It will be shown that it is possible to
    determine the amplitudes of each mode by means of one measured signal at the end
    of the waveguide, even if the transducer and the electronic components are of
    very simple kind.'
author:
- first_name: Jens
  full_name: Rautenberg, Jens
  last_name: Rautenberg
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: 'Rautenberg J, Henning B. Separation of mode-specific signals in a fluid-filled
    circular waveguide. In: <i>Proceedings of the International Congress on Ultrasonics</i>.
    ; 2007.'
  apa: Rautenberg, J., &#38; Henning, B. (2007). Separation of mode-specific signals
    in a fluid-filled circular waveguide. In <i>Proceedings of the International Congress
    on Ultrasonics</i>.
  bibtex: '@inproceedings{Rautenberg_Henning_2007, title={Separation of mode-specific
    signals in a fluid-filled circular waveguide}, booktitle={Proceedings of the International
    Congress on Ultrasonics}, author={Rautenberg, Jens and Henning, Bernd}, year={2007}
    }'
  chicago: Rautenberg, Jens, and Bernd Henning. “Separation of Mode-Specific Signals
    in a Fluid-Filled Circular Waveguide.” In <i>Proceedings of the International
    Congress on Ultrasonics</i>, 2007.
  ieee: J. Rautenberg and B. Henning, “Separation of mode-specific signals in a fluid-filled
    circular waveguide,” in <i>Proceedings of the International Congress on Ultrasonics</i>,
    2007.
  mla: Rautenberg, Jens, and Bernd Henning. “Separation of Mode-Specific Signals in
    a Fluid-Filled Circular Waveguide.” <i>Proceedings of the International Congress
    on Ultrasonics</i>, 2007.
  short: 'J. Rautenberg, B. Henning, in: Proceedings of the International Congress
    on Ultrasonics, 2007.'
date_created: 2019-12-17T13:23:16Z
date_updated: 2022-01-06T06:52:20Z
department:
- _id: '49'
language:
- iso: eng
publication: Proceedings of the International Congress on Ultrasonics
status: public
title: Separation of mode-specific signals in a fluid-filled circular waveguide
type: conference
user_id: '15911'
year: '2007'
...
---
_id: '15341'
author:
- first_name: Hans-Michael
  full_name: Sonnenberg, Hans-Michael
  last_name: Sonnenberg
- first_name: Axel
  full_name: Schmidt-Schoenian, Axel
  last_name: Schmidt-Schoenian
- first_name: Jens
  full_name: Rautenberg, Jens
  last_name: Rautenberg
- first_name: Carsten
  full_name: Unverzagt, Carsten
  last_name: Unverzagt
- first_name: Romina
  full_name: Kehl, Romina
  last_name: Kehl
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: Sonnenberg H-M, Schmidt-Schoenian A, Rautenberg J, Unverzagt C, Kehl R, Henning
    B. <i>Ultraschallzähler</i>.; 2007.
  apa: Sonnenberg, H.-M., Schmidt-Schoenian, A., Rautenberg, J., Unverzagt, C., Kehl,
    R., &#38; Henning, B. (2007). <i>Ultraschallzähler</i>.
  bibtex: '@book{Sonnenberg_Schmidt-Schoenian_Rautenberg_Unverzagt_Kehl_Henning_2007,
    title={Ultraschallzähler}, author={Sonnenberg, Hans-Michael and Schmidt-Schoenian,
    Axel and Rautenberg, Jens and Unverzagt, Carsten and Kehl, Romina and Henning,
    Bernd}, year={2007} }'
  chicago: Sonnenberg, Hans-Michael, Axel Schmidt-Schoenian, Jens Rautenberg, Carsten
    Unverzagt, Romina Kehl, and Bernd Henning. <i>Ultraschallzähler</i>, 2007.
  ieee: H.-M. Sonnenberg, A. Schmidt-Schoenian, J. Rautenberg, C. Unverzagt, R. Kehl,
    and B. Henning, <i>Ultraschallzähler</i>. 2007.
  mla: Sonnenberg, Hans-Michael, et al. <i>Ultraschallzähler</i>. 2007.
  short: H.-M. Sonnenberg, A. Schmidt-Schoenian, J. Rautenberg, C. Unverzagt, R. Kehl,
    B. Henning, Ultraschallzähler, 2007.
date_created: 2019-12-17T13:24:08Z
date_updated: 2022-01-06T06:52:20Z
department:
- _id: '49'
language:
- iso: eng
status: public
title: Ultraschallzähler
type: misc
user_id: '15911'
year: '2007'
...
---
_id: '15342'
abstract:
- lang: eng
  text: "In der Ultraschallmesstechnik ist der Einsatz des Impuls-Echoverfahrens verbreitet.
    Wird nur ein Ultraschallwandler eingesetzt, benötigt man für das sequentielle
    Senden und Empfangen einen Sende-/Empfangsumschalter. Häufig werden aber nicht
    nur Impulse gesendet, sondern auch sogenannte Bursts, die aus mehreren Wellenzügen
    bestehen. Die während des Sendebetriebs empfangenen Ultraschallwellen, die z.
    B. durch Reflexionen von nahe gelegenen Hindernissen entstehen, können bei diesen
    umschaltenden Systemen nicht ausgewertet werden.\r\nIn diesem Beitrag wird eine
    Sensor-Interface-Elektronik vorgestellt, die das gleichzeitige Senden und Empfangen
    von Ultraschallsignalen mit nur einem Ultraschallwandler erlaubt. Die dazu erforderliche
    Trennung von Sende- und Empfangssignal wird durch einen Richtkoppler ermöglicht,
    der mit vergleichsweise geringem technischem Aufwand aus Breitbandübertragern
    aufgebaut ist. Eine geeignete Dimensionierung für die verkoppelten Übertrager
    wurde durch die Analyse der zugehörigen Streumatrix dieses Aufbaus gefunden. Die
    Arbeitsweise sowie die Bedeutung der Anpassung der Tore des Richtkopplers wird
    anhand der Ankopplung verschiedener Medien an den Wandler erläutert. Die angekoppelte
    akustische Last beeinflusst dabei auch die elektrischen Eigenschaften des Sensors.\r\nDurch
    den Einsatz dieser Sensorelektronik wird es möglich, Reflexionen in unmittelbarer
    Nähe der Sensoroberfläche aufzunehmen, ohne dass z. B. Vorlaufkörper eingesetzt
    werden müssen. Möglichkeiten zur selbsttätigen Abstimmung der Sensorelektronik
    auf den angeschlossenen Ultraschallwandler bzw. dessen Parameteränderungen werden
    diskutiert."
author:
- first_name: Torsten
  full_name: Vössing, Torsten
  last_name: Vössing
- first_name: Jens
  full_name: Rautenberg, Jens
  last_name: Rautenberg
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: 'Vössing T, Rautenberg J, Henning B. Sensorelektronik zur Bestimmung von Reflexionen
    sensoroberflächennaher Schichten. In: Mehra S-R, ed. <i>Fortschritte Der Akustik</i>.
    Berlin: Dt. Ges. für Akustik; 2007.'
  apa: 'Vössing, T., Rautenberg, J., &#38; Henning, B. (2007). Sensorelektronik zur
    Bestimmung von Reflexionen sensoroberflächennaher Schichten. In S.-R. Mehra (Ed.),
    <i>Fortschritte der Akustik</i>. Berlin: Dt. Ges. für Akustik.'
  bibtex: '@inproceedings{Vössing_Rautenberg_Henning_2007, place={Berlin}, title={Sensorelektronik
    zur Bestimmung von Reflexionen sensoroberflächennaher Schichten}, booktitle={Fortschritte
    der Akustik}, publisher={Dt. Ges. für Akustik}, author={Vössing, Torsten and Rautenberg,
    Jens and Henning, Bernd}, editor={Mehra, Schew-RamEditor}, year={2007} }'
  chicago: 'Vössing, Torsten, Jens Rautenberg, and Bernd Henning. “Sensorelektronik
    Zur Bestimmung von Reflexionen Sensoroberflächennaher Schichten.” In <i>Fortschritte
    Der Akustik</i>, edited by Schew-Ram Mehra. Berlin: Dt. Ges. für Akustik, 2007.'
  ieee: T. Vössing, J. Rautenberg, and B. Henning, “Sensorelektronik zur Bestimmung
    von Reflexionen sensoroberflächennaher Schichten,” in <i>Fortschritte der Akustik</i>,
    2007.
  mla: Vössing, Torsten, et al. “Sensorelektronik Zur Bestimmung von Reflexionen Sensoroberflächennaher
    Schichten.” <i>Fortschritte Der Akustik</i>, edited by Schew-Ram Mehra, Dt. Ges.
    für Akustik, 2007.
  short: 'T. Vössing, J. Rautenberg, B. Henning, in: S.-R. Mehra (Ed.), Fortschritte
    Der Akustik, Dt. Ges. für Akustik, Berlin, 2007.'
date_created: 2019-12-17T13:25:15Z
date_updated: 2022-01-06T06:52:20Z
department:
- _id: '49'
editor:
- first_name: Schew-Ram
  full_name: Mehra, Schew-Ram
  last_name: Mehra
language:
- iso: eng
place: Berlin
publication: Fortschritte der Akustik
publication_identifier:
  isbn:
  - '9783980865937'
publisher: Dt. Ges. für Akustik
status: public
title: Sensorelektronik zur Bestimmung von Reflexionen sensoroberflächennaher Schichten
type: conference
user_id: '15911'
year: '2007'
...
---
_id: '15343'
abstract:
- lang: eng
  text: "In der Ultraschallmesstechnik ist der Einsatz des Impuls-Echoverfahrens verbreitet.
    Wird nur ein Ultraschallwandler eingesetzt, benötigt man für das sequentielle
    Senden und Empfangen einen Sende-/Empfangsumschalter. Häufig werden aber nicht
    nur Impulse gesendet, sondern auch sogenannte Bursts, die aus mehreren Wellenzügen
    bestehen. Die während des Sendebetriebs empfangenen Ultraschallwellen, die z.
    B. durch Reflexionen von nahe gelegenen Hindernissen entstehen, können bei diesen
    umschaltenden Systemen nicht ausgewertet werden.\r\nIn diesem Beitrag wird eine
    Sensor-Interface-Elektronik vorgestellt, die das gleichzeitige Senden und Empfangen
    von Ultraschallsignalen mit nur einem Ultraschallwandler erlaubt. Die dazu erforderliche
    Trennung von Sende- und Empfangssignal wird durch einen Richtkoppler ermöglicht,
    der mit vergleichsweise geringem technischem Aufwand aus Breitbandübertragern
    aufgebaut ist. Eine geeignete Dimensionierung für die verkoppelten Übertrager
    wurde durch die Analyse der zugehörigen Streumatrix dieses Aufbaus gefunden. Die
    Arbeitsweise sowie die Bedeutung der Anpassung der Tore des Richtkopplers wird
    anhand der Ankopplung verschiedener Medien an den Wandler erläutert. Die angekoppelte
    akustische Last beeinflusst dabei auch die elektrischen Eigenschaften des Sensors.\r\nDurch
    den Einsatz dieser Sensorelektronik wird es möglich, Reflexionen in unmittelbarer
    Nähe der Sensoroberfläche aufzunehmen, ohne dass z. B. Vorlaufkörper eingesetzt
    werden müssen. Möglichkeiten zur selbsttätigen Abstimmung der Sensorelektronik
    auf den angeschlossenen Ultraschallwandler bzw. dessen Parameteränderungen werden
    diskutiert."
author:
- first_name: Torsten
  full_name: Vössing, Torsten
  last_name: Vössing
- first_name: Jens
  full_name: Rautenberg, Jens
  last_name: Rautenberg
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: 'Vössing T, Rautenberg J, Henning B. Sensorelektronik zur Bestimmung von Reflexionen
    sensoroberflächennaher Schichten. In: Mehra S-R, ed. <i>Fortschritte Der Akustik</i>.
    Berlin: Dt. Ges. für Akustik; 2007.'
  apa: 'Vössing, T., Rautenberg, J., &#38; Henning, B. (2007). Sensorelektronik zur
    Bestimmung von Reflexionen sensoroberflächennaher Schichten. In S.-R. Mehra (Ed.),
    <i>Fortschritte der Akustik</i>. Berlin: Dt. Ges. für Akustik.'
  bibtex: '@inproceedings{Vössing_Rautenberg_Henning_2007, place={Berlin}, title={Sensorelektronik
    zur Bestimmung von Reflexionen sensoroberflächennaher Schichten}, booktitle={Fortschritte
    der Akustik}, publisher={Dt. Ges. für Akustik}, author={Vössing, Torsten and Rautenberg,
    Jens and Henning, Bernd}, editor={Mehra, Schew-RamEditor}, year={2007} }'
  chicago: 'Vössing, Torsten, Jens Rautenberg, and Bernd Henning. “Sensorelektronik
    Zur Bestimmung von Reflexionen Sensoroberflächennaher Schichten.” In <i>Fortschritte
    Der Akustik</i>, edited by Schew-Ram Mehra. Berlin: Dt. Ges. für Akustik, 2007.'
  ieee: T. Vössing, J. Rautenberg, and B. Henning, “Sensorelektronik zur Bestimmung
    von Reflexionen sensoroberflächennaher Schichten,” in <i>Fortschritte der Akustik</i>,
    Stuttgar, 2007.
  mla: Vössing, Torsten, et al. “Sensorelektronik Zur Bestimmung von Reflexionen Sensoroberflächennaher
    Schichten.” <i>Fortschritte Der Akustik</i>, edited by Schew-Ram Mehra, Dt. Ges.
    für Akustik, 2007.
  short: 'T. Vössing, J. Rautenberg, B. Henning, in: S.-R. Mehra (Ed.), Fortschritte
    Der Akustik, Dt. Ges. für Akustik, Berlin, 2007.'
conference:
  end_date: '22.03.2007 '
  location: Stuttgar
  name: 3. Deutsche Jahrestagung für Akustik (DAGA 2007)
  start_date: '19.03.2007 '
date_created: 2019-12-17T13:31:04Z
date_updated: 2022-01-06T06:52:20Z
department:
- _id: '49'
editor:
- first_name: Schew-Ram
  full_name: Mehra, Schew-Ram
  last_name: Mehra
language:
- iso: eng
place: Berlin
publication: Fortschritte der Akustik
publication_identifier:
  isbn:
  - '9783980865937'
publisher: Dt. Ges. für Akustik
status: public
title: Sensorelektronik zur Bestimmung von Reflexionen sensoroberflächennaher Schichten
type: conference
user_id: '15911'
year: '2007'
...
---
_id: '15344'
abstract:
- lang: eng
  text: In many applications ultrasonic transducers are used for transmitting and
    receiving ultrasonic waves. Ultrasonic sensor systems meet the practical requirements
    of industrial applications quite well. Typical sensor applications are for example
    the measurement of distance and thickness. Especially if only one ultrasonic transceiver
    and the well-known pulse-echo-method are used, the sensor electronics has to switch
    from transmitting to receiving mode. This is one of the most limiting properties
    because the probe can not receive echoes from nearby obstacles or thin material
    layers. This contribution deals with the development of an electronic interface
    circuit for ultrasonic sensors allowing transmitting and receiving of acoustic
    signals simultaneously. There are already several methods to separate the transmitted
    from the received signal for instance the well-known circulator in the telephone,
    the differential transformer mentioned by Bradfield [1] or a directional coupler
    [2]. The directional coupler consists of two broadband transformers linked with
    each other in such a way that it equally distributes the input power at port one
    to the third and fourth port, while port two is isolated. This circuit is also
    known as 3 dB directional coupler and makes it possible to get reference echoes
    directly from the interface between the sensor and the medium of interest. Several
    reflectors or multiple sound paths such as used in ultrasonic density measurement
    systems are unnecessary [3].
author:
- first_name: Torsten
  full_name: Vössing, Torsten
  last_name: Vössing
- first_name: Jens
  full_name: Rautenberg, Jens
  last_name: Rautenberg
- first_name: Romina
  full_name: Kehl, Romina
  last_name: Kehl
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: 'Vössing T, Rautenberg J, Kehl R, Henning B. Simultaneous transmitting and
    receiving with ultrasonic sensors. In: ; 2007.'
  apa: Vössing, T., Rautenberg, J., Kehl, R., &#38; Henning, B. (2007). Simultaneous
    transmitting and receiving with ultrasonic sensors. Presented at the 3th International
    Conference Sensor + Test 2007, Nuremberg.
  bibtex: '@inproceedings{Vössing_Rautenberg_Kehl_Henning_2007, title={Simultaneous
    transmitting and receiving with ultrasonic sensors}, author={Vössing, Torsten
    and Rautenberg, Jens and Kehl, Romina and Henning, Bernd}, year={2007} }'
  chicago: Vössing, Torsten, Jens Rautenberg, Romina Kehl, and Bernd Henning. “Simultaneous
    Transmitting and Receiving with Ultrasonic Sensors,” 2007.
  ieee: T. Vössing, J. Rautenberg, R. Kehl, and B. Henning, “Simultaneous transmitting
    and receiving with ultrasonic sensors,” presented at the 3th International Conference
    Sensor + Test 2007, Nuremberg, 2007.
  mla: Vössing, Torsten, et al. <i>Simultaneous Transmitting and Receiving with Ultrasonic
    Sensors</i>. 2007.
  short: 'T. Vössing, J. Rautenberg, R. Kehl, B. Henning, in: 2007.'
conference:
  end_date: 24.05.2007
  location: Nuremberg
  name: 3th International Conference Sensor + Test 2007
  start_date: 22.05.2007
date_created: 2019-12-17T14:22:24Z
date_updated: 2022-01-06T06:52:21Z
department:
- _id: '49'
language:
- iso: eng
publication_identifier:
  isbn:
  - 978-3-9810993-2-4
status: public
title: Simultaneous transmitting and receiving with ultrasonic sensors
type: conference
user_id: '15911'
year: '2007'
...
---
_id: '15345'
abstract:
- lang: eng
  text: In this contribution the application of a directional coupler for analysing
    reference reflections from thin layers in ultrasonic measurement of the characteristic
    acoustic impedance is presented. In a prior work ([2]) it was shown, that a directional
    coupler can be used in combination with an ultrasonic transducer to get reflections
    from layers that are very close to the transducers surface. Since the directional
    coupler provides the opportunity to send and receive signals at the same time,
    these layers can be very thin ({\textless} 1 mm). Reflections that arrive at the
    transducer during the sending process can be analysed because the directional
    coupler separates the receiving signal from the input signal of the transducer.
    When only one transducer is used to measure the acoustic impedance of a liquid
    the reflections from the thin layer reach the transducer after a very short time.
    The reflections sum up and with the concept of reflection and transmission coefficients
    a relation is found between the measured amplitude and a reference amplitude which
    was measured before. The exciting signal could be a burst of some periods of a
    sinusoidal alternating voltage. The advantages of using thin layers for the described
    task are the small geometry that allows flexible application of the sensor and
    the minimisation of temperature gradients within the medium because thin layers
    can follow thermal fluctuations faster than thick ones. In this paper the functional
    principle and first achievements are presented.
author:
- first_name: Torsten
  full_name: Vössing, Torsten
  last_name: Vössing
- first_name: Jens
  full_name: Rautenberg, Jens
  last_name: Rautenberg
- first_name: Andreas
  full_name: Schröder, Andreas
  last_name: Schröder
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: 'Vössing T, Rautenberg J, Schröder A, Henning B. Ultrasonic measurement of
    the characteristic acoustic impedance using a directional coupler to analyse reference
    reflections from thin layers. In: ; 2007.'
  apa: Vössing, T., Rautenberg, J., Schröder, A., &#38; Henning, B. (2007). Ultrasonic
    measurement of the characteristic acoustic impedance using a directional coupler
    to analyse reference reflections from thin layers. Presented at the 8th International
    Conference on Electronic Measurement &#38; Instruments, ICEMI 2007, Xi’An, China.
  bibtex: '@inproceedings{Vössing_Rautenberg_Schröder_Henning_2007, title={Ultrasonic
    measurement of the characteristic acoustic impedance using a directional coupler
    to analyse reference reflections from thin layers}, author={Vössing, Torsten and
    Rautenberg, Jens and Schröder, Andreas and Henning, Bernd}, year={2007} }'
  chicago: Vössing, Torsten, Jens Rautenberg, Andreas Schröder, and Bernd Henning.
    “Ultrasonic Measurement of the Characteristic Acoustic Impedance Using a Directional
    Coupler to Analyse Reference Reflections from Thin Layers,” 2007.
  ieee: T. Vössing, J. Rautenberg, A. Schröder, and B. Henning, “Ultrasonic measurement
    of the characteristic acoustic impedance using a directional coupler to analyse
    reference reflections from thin layers,” presented at the 8th International Conference
    on Electronic Measurement &#38; Instruments, ICEMI 2007, Xi’An, China, 2007.
  mla: Vössing, Torsten, et al. <i>Ultrasonic Measurement of the Characteristic Acoustic
    Impedance Using a Directional Coupler to Analyse Reference Reflections from Thin
    Layers</i>. 2007.
  short: 'T. Vössing, J. Rautenberg, A. Schröder, B. Henning, in: 2007.'
conference:
  end_date: 18.08.2007
  location: Xi’An, China
  name: 8th International Conference on Electronic Measurement & Instruments, ICEMI
    2007
  start_date: 16.08.2007
date_created: 2019-12-17T14:27:14Z
date_updated: 2022-01-06T06:52:21Z
department:
- _id: '49'
language:
- iso: eng
status: public
title: Ultrasonic measurement of the characteristic acoustic impedance using a directional
  coupler to analyse reference reflections from thin layers
type: conference
user_id: '15911'
year: '2007'
...
---
_id: '15347'
abstract:
- lang: eng
  text: "Um das Schwingungsverhalten eines mit Flüssigkeit\r\ngefüllten zylindrischen
    Stahltanks mit beliebiger Füllhöhe zu\r\nmodellieren, werden Ansätze aus der Schalentheorie
    genutzt.\r\nVerschiedene analytische Modelle und Vereinfachungen\r\nwerden gegenübergestellt
    und für den leeren sowie komplett\r\ngefüllten Zylinder gelöst. Zudem wird ein
    semianalytisches\r\nModell für den teilweise gefüllten Zylinder entworfen.\r\nSimulationsergebnisse
    aus FEM-Simulationen sowie\r\nErgebnisse aus Testmessungen werden den Modellwerten\r\ngegenübergestellt."
author:
- first_name: Romina
  full_name: Kehl, Romina
  last_name: Kehl
- first_name: Jens
  full_name: Rautenberg, Jens
  last_name: Rautenberg
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: 'Kehl R, Rautenberg J, Henning B. Schwingungsverhalten eines flüssigkeitsgefüllten
    Tanks. In: ; 2006:407-408.'
  apa: Kehl, R., Rautenberg, J., &#38; Henning, B. (2006). Schwingungsverhalten eines
    flüssigkeitsgefüllten Tanks (pp. 407–408). Presented at the 32. Deutsche Jahrestagung
    für Akustik (DAGA 2006), Braunschweig.
  bibtex: '@inproceedings{Kehl_Rautenberg_Henning_2006, title={Schwingungsverhalten
    eines flüssigkeitsgefüllten Tanks}, author={Kehl, Romina and Rautenberg, Jens
    and Henning, Bernd}, year={2006}, pages={407–408} }'
  chicago: Kehl, Romina, Jens Rautenberg, and Bernd Henning. “Schwingungsverhalten
    Eines Flüssigkeitsgefüllten Tanks,” 407–8, 2006.
  ieee: R. Kehl, J. Rautenberg, and B. Henning, “Schwingungsverhalten eines flüssigkeitsgefüllten
    Tanks,” presented at the 32. Deutsche Jahrestagung für Akustik (DAGA 2006), Braunschweig,
    2006, pp. 407–408.
  mla: Kehl, Romina, et al. <i>Schwingungsverhalten Eines Flüssigkeitsgefüllten Tanks</i>.
    2006, pp. 407–08.
  short: 'R. Kehl, J. Rautenberg, B. Henning, in: 2006, pp. 407–408.'
conference:
  end_date: 23.03.2006
  location: Braunschweig
  name: 32. Deutsche Jahrestagung für Akustik (DAGA 2006)
  start_date: 21.03.2006
date_created: 2019-12-17T14:30:29Z
date_updated: 2022-01-06T06:52:21Z
department:
- _id: '49'
language:
- iso: eng
page: 407-408
status: public
title: Schwingungsverhalten eines flüssigkeitsgefüllten Tanks
type: conference
user_id: '15911'
year: '2006'
...
---
_id: '15348'
abstract:
- lang: eng
  text: In spite of the outstanding importance of neuronavigational techniques the
    neurosurgeon has still highly to rely on his visual as well as tactile sense and
    his experience in distinguishing tumor tissue from intact brain parenchyma. All
    the more - as neuronavigation is based on preoperative imaging scans - considerable
    brain shift may occur during surgery and that will lead to erroneous results.
    Furthermore the surgeon loses his tactile sense during endoscopic surgery. Therefore
    control of tissue manipulation is limited today to the fiberoptic image techniques,
    possibly ensured by neuronavigational supervision or haptic feedback systems.
    In robotic guided surgery the missing tactile sensing will be particularly crucial.
    The human sense of touch is a highly complex sensory perception comprising epicritical
    and propiozeptive information processing. The development of a tool for intraoperative
    tactile perception will be a highly challenging task to improve the safety during
    surgery. Different sensor concepts (elasticity probe and resonant piezoelectric
    sensor) have been set up and adapted to distinguish elasticity differences in
    soft tissue mimicking gel phantoms. The elasticity probe is based on two leaf
    springs of different bending stiffness. The two tips of the beams act both on
    the material to be tested. The two deflections measured by strain gauges are processed
    in a mathematical model calculating the phantoms' stiffness. In contrast to this
    differential sensing concept the piezoelectric sensor, which is driven at its
    resonance, measures stiffness and damping of the phantoms by evaluating frequency
    or phase shift and amplitude change. Gelatine gels of different concentrations
    (5{\%}, 10{\%}, 20{\%} of gelatine) have been used for a characterization of sensor
    elements and their sensitivity to elasticity distinctions. Using the hand-guided
    elasticity probe the determination of gel elasticity is performed with high reliability.
    By constant mechanical load the piezoelectric sensor also presents a proportional
    dependency of tissue elasticity.
author:
- first_name: Romina
  full_name: Kehl, Romina
  last_name: Kehl
- first_name: Ralf
  full_name: Stroop, Ralf
  last_name: Stroop
- first_name: David
  full_name: Oliva Uribe, David
  last_name: Oliva Uribe
- first_name: Tobias
  full_name: Hemsel, Tobias
  last_name: Hemsel
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: 'Kehl R, Stroop R, Oliva Uribe D, Hemsel T, Henning B. Tactile sensors for
    determination of elastic properties of brain tissue mimicking phantoms. In: ;
    2006.'
  apa: Kehl, R., Stroop, R., Oliva Uribe, D., Hemsel, T., &#38; Henning, B. (2006).
    Tactile sensors for determination of elastic properties of brain tissue mimicking
    phantoms. Presented at the Jahrestagung der Deutschen Gesellschaft für Computer-
    und Roboterassistierte Chirurgie (CURAC 2006), Hannover.
  bibtex: '@inproceedings{Kehl_Stroop_Oliva Uribe_Hemsel_Henning_2006, title={Tactile
    sensors for determination of elastic properties of brain tissue mimicking phantoms},
    author={Kehl, Romina and Stroop, Ralf and Oliva Uribe, David and Hemsel, Tobias
    and Henning, Bernd}, year={2006} }'
  chicago: Kehl, Romina, Ralf Stroop, David Oliva Uribe, Tobias Hemsel, and Bernd
    Henning. “Tactile Sensors for Determination of Elastic Properties of Brain Tissue
    Mimicking Phantoms,” 2006.
  ieee: R. Kehl, R. Stroop, D. Oliva Uribe, T. Hemsel, and B. Henning, “Tactile sensors
    for determination of elastic properties of brain tissue mimicking phantoms,” presented
    at the Jahrestagung der Deutschen Gesellschaft für Computer- und Roboterassistierte
    Chirurgie (CURAC 2006), Hannover, 2006.
  mla: Kehl, Romina, et al. <i>Tactile Sensors for Determination of Elastic Properties
    of Brain Tissue Mimicking Phantoms</i>. 2006.
  short: 'R. Kehl, R. Stroop, D. Oliva Uribe, T. Hemsel, B. Henning, in: 2006.'
conference:
  end_date: 14.10.2006
  location: Hannover
  name: Jahrestagung der Deutschen Gesellschaft für Computer- und Roboterassistierte
    Chirurgie (CURAC 2006)
  start_date: 12.10.2006
date_created: 2019-12-17T14:33:15Z
date_updated: 2022-01-06T06:52:21Z
department:
- _id: '49'
language:
- iso: eng
status: public
title: Tactile sensors for determination of elastic properties of brain tissue mimicking
  phantoms
type: conference
user_id: '15911'
year: '2006'
...
---
_id: '15349'
abstract:
- lang: eng
  text: "Die kontinuierliche und zuverlässige Konzentrationsmessung in Flüssigkeiten\r\nob
    zur Dosierung oder Prozessverfolgung stellt auch heute noch eine große\r\nmesstechnische
    Herausforderung dar. Akustische Sensorsysteme sind für diese\r\nMessaufgabe insbesondere
    unter industriellen Einsatzbedingungen prädestiniert.\r\nEs gibt eine Vielzahl
    verschiedener sorgfältig entworfener Ultraschallsensoren,\r\ndie diese Aufgabe
    durch Bestimmung der Schallgeschwindigkeit und\r\nder akustischen Impedanz lösen.
    Sie basieren meist auf senkrechten Durchgängen\r\ndes Schalls durch Grenzschichten,
    was sie sehr empfindlich gegenüber Ablagerungen\r\nmacht.\r\nDieser Beitrag liefert
    einen neuen Ansatz, indem die gesamte Oberfläche des\r\nMessraumes als akustischer
    Wellenleiter gestaltet und genutzt wird. Es hat sich\r\ngezeigt, dass sich durch
    Ausnutzen verschiedener Simulationswerkzeuge die\r\nHauptkomponenten eines Empfangssignals
    berechnen lassen, die eindeutig den\r\nverschiedenen modalen Anteilen zugeordnet
    werden können. Damit ist es möglich,\r\nallein aus dem Empfangssignal eines herkömmlichen
    Ultraschallwandlers\r\nauf die modalen Anteilsfaktoren zu schließen. Mit Hilfe
    dieser Koeffizienten\r\nund eines Modells des akustischen Wellenleiters lässt
    sich ein Gleichungssystem\r\naufstellen, das den Zusammenhang zwischen Dissipation
    in der Flüssigkeit\r\nsowie der durch Wellenleitergeometrie und Impedanzverhältnisse
    bedingten\r\nSignaldämpfung und den Amplituden der modalen Anteilsfaktoren beschreibt."
author:
- first_name: Jens
  full_name: Rautenberg, Jens
  last_name: Rautenberg
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: 'Rautenberg J, Henning B. Messung der akustischen Impedanz einer Flüssigkeit
    in einem akustischen Wellenleiter. In: ; 2006:55-73.'
  apa: Rautenberg, J., &#38; Henning, B. (2006). Messung der akustischen Impedanz
    einer Flüssigkeit in einem akustischen Wellenleiter (pp. 55–73). Presented at
    the XX. Messtechnisches Symposium 2006 (AHMT), Bayreuth.
  bibtex: '@inproceedings{Rautenberg_Henning_2006, title={Messung der akustischen
    Impedanz einer Flüssigkeit in einem akustischen Wellenleiter}, author={Rautenberg,
    Jens and Henning, Bernd}, year={2006}, pages={55–73} }'
  chicago: Rautenberg, Jens, and Bernd Henning. “Messung Der Akustischen Impedanz
    Einer Flüssigkeit in Einem Akustischen Wellenleiter,” 55–73, 2006.
  ieee: J. Rautenberg and B. Henning, “Messung der akustischen Impedanz einer Flüssigkeit
    in einem akustischen Wellenleiter,” presented at the XX. Messtechnisches Symposium
    2006 (AHMT), Bayreuth, 2006, pp. 55–73.
  mla: Rautenberg, Jens, and Bernd Henning. <i>Messung Der Akustischen Impedanz Einer
    Flüssigkeit in Einem Akustischen Wellenleiter</i>. 2006, pp. 55–73.
  short: 'J. Rautenberg, B. Henning, in: 2006, pp. 55–73.'
conference:
  end_date: 07.10.2006
  location: Bayreuth
  name: XX. Messtechnisches Symposium 2006 (AHMT)
  start_date: 05.10.2006
date_created: 2019-12-17T14:34:33Z
date_updated: 2022-01-06T06:52:21Z
department:
- _id: '49'
language:
- iso: eng
page: 55-73
publication_identifier:
  isbn:
  - 978-3-8322-5419-3
status: public
title: Messung der akustischen Impedanz einer Flüssigkeit in einem akustischen Wellenleiter
type: conference
user_id: '15911'
year: '2006'
...
---
_id: '15350'
abstract:
- lang: eng
  text: In many different ultrasound applications mirrors are often used to deflect
    ultrasonic waves. The dimensions of the mirror and the applied materials have
    an essential influence on the output signal characteristics and the obtained measuring
    quantities. The extension of mirror geometry is not necessarily associated with
    a higher reflection coefficient. This can be explained with the aid of coincidence
    condition. A second criterion aims at the avoidance of the mirror resonance. This
    two conditions lead to an optimal dimensioning of mirror geometry with given material
    properties and operation mode, as exemplified for a rectangular mirror.
author:
- first_name: Carsten
  full_name: Unverzagt, Carsten
  last_name: Unverzagt
- first_name: Jens
  full_name: Rautenberg, Jens
  last_name: Rautenberg
- first_name: Romina
  full_name: Kehl, Romina
  last_name: Kehl
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: 'Unverzagt C, Rautenberg J, Kehl R, Henning B. Optimization of ultrasound reflecting
    mirrors. In: <i>2006 IEEE International Ultrasonics Symposium</i>. ; 2006:1390-1393.'
  apa: Unverzagt, C., Rautenberg, J., Kehl, R., &#38; Henning, B. (2006). Optimization
    of ultrasound reflecting mirrors. In <i>2006 IEEE International Ultrasonics Symposium</i>
    (pp. 1390–1393).
  bibtex: '@inproceedings{Unverzagt_Rautenberg_Kehl_Henning_2006, title={Optimization
    of ultrasound reflecting mirrors}, booktitle={2006 IEEE International Ultrasonics
    Symposium}, author={Unverzagt, Carsten and Rautenberg, Jens and Kehl, Romina and
    Henning, Bernd}, year={2006}, pages={1390–1393} }'
  chicago: Unverzagt, Carsten, Jens Rautenberg, Romina Kehl, and Bernd Henning. “Optimization
    of Ultrasound Reflecting Mirrors.” In <i>2006 IEEE International Ultrasonics Symposium</i>,
    1390–93, 2006.
  ieee: C. Unverzagt, J. Rautenberg, R. Kehl, and B. Henning, “Optimization of ultrasound
    reflecting mirrors,” in <i>2006 IEEE International Ultrasonics Symposium</i>,
    2006, pp. 1390–1393.
  mla: Unverzagt, Carsten, et al. “Optimization of Ultrasound Reflecting Mirrors.”
    <i>2006 IEEE International Ultrasonics Symposium</i>, 2006, pp. 1390–93.
  short: 'C. Unverzagt, J. Rautenberg, R. Kehl, B. Henning, in: 2006 IEEE International
    Ultrasonics Symposium, 2006, pp. 1390–1393.'
date_created: 2019-12-17T15:35:07Z
date_updated: 2022-01-06T06:52:21Z
department:
- _id: '49'
language:
- iso: eng
page: 1390-1393
publication: 2006 IEEE International Ultrasonics Symposium
status: public
title: Optimization of ultrasound reflecting mirrors
type: conference
user_id: '15911'
year: '2006'
...
---
_id: '15351'
abstract:
- lang: eng
  text: Today's automotive headlights are built with transparent cover lenses. Therefore
    condensation of water leads to a visible optical defect. This paper presents a
    new approach for determination of the droplet size using colour phenomena in totally
    reflected light. It is based on a model of the generation of colour patterns by
    interference of several rays of light each multiple totally reflected inside condensed
    droplets. The droplet size may be determined by the colour if the contact angle
    is known. Measurement of both droplet size and colour all
author:
- first_name: Dietmar
  full_name: Wetzlar, Dietmar
  last_name: Wetzlar
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
- first_name: Sascha
  full_name: Nolte, Sascha
  last_name: Nolte
- first_name: Jens
  full_name: Klahold, Jens
  last_name: Klahold
citation:
  ama: 'Wetzlar D, Henning B, Nolte S, Klahold J. Investigation of colour phenomena
    in condensed water droplets. In: ; 2006.'
  apa: Wetzlar, D., Henning, B., Nolte, S., &#38; Klahold, J. (2006). Investigation
    of colour phenomena in condensed water droplets. Presented at the  OPTO &#38;
    IRS<sup>2</sup> 2006 Conference, Nürenberg.
  bibtex: '@inproceedings{Wetzlar_Henning_Nolte_Klahold_2006, title={Investigation
    of colour phenomena in condensed water droplets}, author={Wetzlar, Dietmar and
    Henning, Bernd and Nolte, Sascha and Klahold, Jens}, year={2006} }'
  chicago: Wetzlar, Dietmar, Bernd Henning, Sascha Nolte, and Jens Klahold. “Investigation
    of Colour Phenomena in Condensed Water Droplets,” 2006.
  ieee: D. Wetzlar, B. Henning, S. Nolte, and J. Klahold, “Investigation of colour
    phenomena in condensed water droplets,” presented at the  OPTO &#38; IRS<sup>2</sup>
    2006 Conference, Nürenberg, 2006.
  mla: Wetzlar, Dietmar, et al. <i>Investigation of Colour Phenomena in Condensed
    Water Droplets</i>. 2006.
  short: 'D. Wetzlar, B. Henning, S. Nolte, J. Klahold, in: 2006.'
conference:
  end_date: 01.06.2006
  location: Nürenberg
  name: ' OPTO & IRS² 2006 Conference'
  start_date: 30.05.2006
date_created: 2019-12-17T15:35:59Z
date_updated: 2022-01-06T06:52:21Z
department:
- _id: '49'
language:
- iso: eng
publication_identifier:
  isbn:
  - 978-3-9810993-0-0
status: public
title: Investigation of colour phenomena in condensed water droplets
type: conference
user_id: '15911'
year: '2006'
...
---
_id: '15357'
author:
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
- first_name: Jens
  full_name: Rautenberg, Jens
  last_name: Rautenberg
citation:
  ama: Henning B, Rautenberg J. Process monitoring using ultrasonic sensor systems.
    <i>Ultrasonics</i>. 2006;(44):e1395-e1399.
  apa: Henning, B., &#38; Rautenberg, J. (2006). Process monitoring using ultrasonic
    sensor systems. <i>Ultrasonics</i>, (44), e1395–e1399.
  bibtex: '@article{Henning_Rautenberg_2006, title={Process monitoring using ultrasonic
    sensor systems}, number={44}, journal={Ultrasonics}, author={Henning, Bernd and
    Rautenberg, Jens}, year={2006}, pages={e1395–e1399} }'
  chicago: 'Henning, Bernd, and Jens Rautenberg. “Process Monitoring Using Ultrasonic
    Sensor Systems.” <i>Ultrasonics</i>, no. 44 (2006): e1395–99.'
  ieee: B. Henning and J. Rautenberg, “Process monitoring using ultrasonic sensor
    systems,” <i>Ultrasonics</i>, no. 44, pp. e1395–e1399, 2006.
  mla: Henning, Bernd, and Jens Rautenberg. “Process Monitoring Using Ultrasonic Sensor
    Systems.” <i>Ultrasonics</i>, no. 44, 2006, pp. e1395–99.
  short: B. Henning, J. Rautenberg, Ultrasonics (2006) e1395–e1399.
date_created: 2019-12-17T15:44:52Z
date_updated: 2022-01-06T06:52:21Z
department:
- _id: '49'
issue: '44'
language:
- iso: eng
page: e1395-e1399
publication: Ultrasonics
status: public
title: Process monitoring using ultrasonic sensor systems
type: journal_article
user_id: '15911'
year: '2006'
...
---
_id: '15346'
author:
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
- first_name: Jens
  full_name: Rautenberg, Jens
  last_name: Rautenberg
citation:
  ama: Henning B, Rautenberg J. Process monitoring using ultrasonic sensor systems.
    <i>Ultrasonics</i>. 2006;(44):e1395-e1399.
  apa: Henning, B., &#38; Rautenberg, J. (2006). Process monitoring using ultrasonic
    sensor systems. <i>Ultrasonics</i>, <i>44</i>, e1395–e1399.
  bibtex: '@article{Henning_Rautenberg_2006, title={Process monitoring using ultrasonic
    sensor systems}, number={44}, journal={Ultrasonics}, author={Henning, Bernd and
    Rautenberg, Jens}, year={2006}, pages={e1395–e1399} }'
  chicago: 'Henning, Bernd, and Jens Rautenberg. “Process Monitoring Using Ultrasonic
    Sensor Systems.” <i>Ultrasonics</i>, no. 44 (2006): e1395–99.'
  ieee: B. Henning and J. Rautenberg, “Process monitoring using ultrasonic sensor
    systems,” <i>Ultrasonics</i>, no. 44, pp. e1395–e1399, 2006.
  mla: Henning, Bernd, and Jens Rautenberg. “Process Monitoring Using Ultrasonic Sensor
    Systems.” <i>Ultrasonics</i>, no. 44, 2006, pp. e1395–99.
  short: B. Henning, J. Rautenberg, Ultrasonics (2006) e1395–e1399.
date_created: 2019-12-17T14:29:21Z
date_updated: 2026-02-25T14:08:09Z
department:
- _id: '49'
issue: '44'
language:
- iso: eng
page: e1395-e1399
publication: Ultrasonics
status: public
title: Process monitoring using ultrasonic sensor systems
type: journal_article
user_id: '15911'
year: '2006'
...
---
_id: '15352'
abstract:
- lang: eng
  text: Impulsbasierte Ultraschallsensorsysteme zur Messung von Füllstand, Durchfluss
    und Konzentration sind heutzutage aufgrund ihrer Robustheit und Wartungsfreundlichkeit
    weit verbreitet. Probleme treten immer dann auf, wenn sich Gasblasen im Medium
    befinden. Diese verändern das empfangene Signal derart, dass eine exakte Messung
    der Schallgeschwindigkeit des flüssigen Mediums nicht mehr möglich ist. Dieser
    Beitrag behandelt eine neue Art der Signalauswertung, die eine zuverlässige Bestimmung
    der Schallgeschwindigkeit auch in diesem Fall gewährleistet. Darüber hinaus können
    auch Rückschlüsse auf den Gasanteil innerhalb des flüssigen Mediums gewonnen werden.
author:
- first_name: Michael
  full_name: Gulsch, Michael
  last_name: Gulsch
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: Gulsch M, Henning B. <i>Bestimmung Des Anteils Ungelöster Gase in Flüssigen
    Medien</i>.; 2005.
  apa: Gulsch, M., &#38; Henning, B. (2005). <i>Bestimmung des Anteils ungelöster
    Gase in flüssigen Medien</i>.
  bibtex: '@book{Gulsch_Henning_2005, title={Bestimmung des Anteils ungelöster Gase
    in flüssigen Medien}, author={Gulsch, Michael and Henning, Bernd}, year={2005}
    }'
  chicago: Gulsch, Michael, and Bernd Henning. <i>Bestimmung Des Anteils Ungelöster
    Gase in Flüssigen Medien</i>, 2005.
  ieee: M. Gulsch and B. Henning, <i>Bestimmung des Anteils ungelöster Gase in flüssigen
    Medien</i>. 2005.
  mla: Gulsch, Michael, and Bernd Henning. <i>Bestimmung Des Anteils Ungelöster Gase
    in Flüssigen Medien</i>. 2005.
  short: M. Gulsch, B. Henning, Bestimmung Des Anteils Ungelöster Gase in Flüssigen
    Medien, 2005.
date_created: 2019-12-17T15:37:43Z
date_updated: 2022-01-06T06:52:21Z
department:
- _id: '49'
language:
- iso: eng
status: public
title: Bestimmung des Anteils ungelöster Gase in flüssigen Medien
type: misc
user_id: '15911'
year: '2005'
...
---
_id: '15353'
abstract:
- lang: eng
  text: Currently there are pulse based ultrasonic sensor systems used to measure
    flow, liquid level, concentration or in process monitoring. In several processes
    the investigated media are a mixture of liquid and solid ingredients (emulsions,
    suspensions). The use of ultrasonic sensor systems will be very complicated if
    gas bubbles appear at the measurement place caused by chemical reactions, high
    temperature or fast flow that means by typical process conditions. Firstly, the
    appearance of gas bubbles falsifies the measured absorption. Secondly, the measured
    velocity is influenced by gas bubbles. In figure 1 is visible that a volume fraction
    of 0.1 ppm of undissolved air decreases the sound velocity by 1.4 m s-1
author:
- first_name: Michael
  full_name: Gulsch, Michael
  last_name: Gulsch
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: 'Gulsch M, Henning B. Bubble detection and gas volume measurement in bubble
    loaded liquids with pulse driven measurement devices. In: <i>2005 IEEE Ultrasonics
    Symposium</i>. ; 2005:780-782.'
  apa: Gulsch, M., &#38; Henning, B. (2005). Bubble detection and gas volume measurement
    in bubble loaded liquids with pulse driven measurement devices. In <i>2005 IEEE
    Ultrasonics Symposium</i> (pp. 780–782).
  bibtex: '@inproceedings{Gulsch_Henning_2005, title={Bubble detection and gas volume
    measurement in bubble loaded liquids with pulse driven measurement devices}, booktitle={2005
    IEEE Ultrasonics Symposium}, author={Gulsch, Michael and Henning, Bernd}, year={2005},
    pages={780–782} }'
  chicago: Gulsch, Michael, and Bernd Henning. “Bubble Detection and Gas Volume Measurement
    in Bubble Loaded Liquids with Pulse Driven Measurement Devices.” In <i>2005 IEEE
    Ultrasonics Symposium</i>, 780–82, 2005.
  ieee: M. Gulsch and B. Henning, “Bubble detection and gas volume measurement in
    bubble loaded liquids with pulse driven measurement devices,” in <i>2005 IEEE
    Ultrasonics Symposium</i>, 2005, pp. 780–782.
  mla: Gulsch, Michael, and Bernd Henning. “Bubble Detection and Gas Volume Measurement
    in Bubble Loaded Liquids with Pulse Driven Measurement Devices.” <i>2005 IEEE
    Ultrasonics Symposium</i>, 2005, pp. 780–82.
  short: 'M. Gulsch, B. Henning, in: 2005 IEEE Ultrasonics Symposium, 2005, pp. 780–782.'
date_created: 2019-12-17T15:39:19Z
date_updated: 2022-01-06T06:52:21Z
department:
- _id: '49'
language:
- iso: eng
page: 780-782
publication: 2005 IEEE Ultrasonics Symposium
status: public
title: Bubble detection and gas volume measurement in bubble loaded liquids with pulse
  driven measurement devices
type: conference
user_id: '15911'
year: '2005'
...
---
_id: '15354'
abstract:
- lang: eng
  text: In vielen verfahrenstechnischen Prozessen ist die kontinuierliche Regelung
    von Prozessgrößen für einen stabilen und sicheren Betrieb eine wichtige Vorraussetzung.
    Die Erfassung der Zielgrößen geschieht aufgrund von hoher Robustheit und Wartungsfreundlichkeit
    zunehmend mit akustischen Messverfahren. Besonders impulsbasierte Messsysteme
    werden häufig zur Messung von Durchfluss, Füllstand und in der Flüssigkeitsanalytik
    auch zur Konzentrationsmessung benutzt. Dabei führen am Messort auftretende Gasblasen
    zu großen messtechnischen Problemen. Sie verändern die gemessenen akustischen
    Stoffkenngrößen, wodurch es zur fehlerhaften Regelung bestimmter Prozesszielgrößen
    kommt.
author:
- first_name: Michael
  full_name: Gulsch, Michael
  last_name: Gulsch
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: 'Gulsch M, Henning B. Gasvolumenmessung in blasenbeladenen Flüssigkeiten. In:
    Fastl H, Fruhmann M, eds. <i>Fortschritte Der Akustik - DAGA ’05</i>. Berlin:
    Deutsche Gesellsch. f. Akustik; 2005:587-588.'
  apa: 'Gulsch, M., &#38; Henning, B. (2005). Gasvolumenmessung in blasenbeladenen
    Flüssigkeiten. In H. Fastl &#38; M. Fruhmann (Eds.), <i>Fortschritte der Akustik
    - DAGA ’05</i> (pp. 587–588). Berlin: Deutsche Gesellsch. f. Akustik.'
  bibtex: '@inproceedings{Gulsch_Henning_2005, place={Berlin}, title={Gasvolumenmessung
    in blasenbeladenen Flüssigkeiten}, booktitle={Fortschritte der Akustik - DAGA
    ’05}, publisher={Deutsche Gesellsch. f. Akustik}, author={Gulsch, Michael and
    Henning, Bernd}, editor={Fastl, Hugo and Fruhmann, MarkusEditors}, year={2005},
    pages={587–588} }'
  chicago: 'Gulsch, Michael, and Bernd Henning. “Gasvolumenmessung in Blasenbeladenen
    Flüssigkeiten.” In <i>Fortschritte Der Akustik - DAGA ’05</i>, edited by Hugo
    Fastl and Markus Fruhmann, 587–88. Berlin: Deutsche Gesellsch. f. Akustik, 2005.'
  ieee: M. Gulsch and B. Henning, “Gasvolumenmessung in blasenbeladenen Flüssigkeiten,”
    in <i>Fortschritte der Akustik - DAGA ’05</i>, 2005, pp. 587–588.
  mla: Gulsch, Michael, and Bernd Henning. “Gasvolumenmessung in Blasenbeladenen Flüssigkeiten.”
    <i>Fortschritte Der Akustik - DAGA ’05</i>, edited by Hugo Fastl and Markus Fruhmann,
    Deutsche Gesellsch. f. Akustik, 2005, pp. 587–88.
  short: 'M. Gulsch, B. Henning, in: H. Fastl, M. Fruhmann (Eds.), Fortschritte Der
    Akustik - DAGA ’05, Deutsche Gesellsch. f. Akustik, Berlin, 2005, pp. 587–588.'
date_created: 2019-12-17T15:40:10Z
date_updated: 2022-01-06T06:52:21Z
department:
- _id: '49'
editor:
- first_name: Hugo
  full_name: Fastl, Hugo
  last_name: Fastl
- first_name: Markus
  full_name: Fruhmann, Markus
  last_name: Fruhmann
language:
- iso: eng
page: 587-588
place: Berlin
publication: Fortschritte der Akustik - DAGA '05
publication_identifier:
  isbn:
  - 3-9808659-1-6
publisher: Deutsche Gesellsch. f. Akustik
status: public
title: Gasvolumenmessung in blasenbeladenen Flüssigkeiten
type: conference
user_id: '15911'
year: '2005'
...
---
_id: '15355'
abstract:
- lang: eng
  text: Today headlights are built with transparent polycarbonate front windows. If
    the air moisture inside the headlight is high and the outside temperature decreases
    below the dew-point, the air moisture condensates inside and the inner surface
    of the polycarbonate front window (PCFW) becomes nontransparent (figure 1). To
    the costumer this appears as an optical defect.In order to avoid the condensation
    and to speed up the evaporation of the condensed water (condensate) on the PCFW
    a Computational-Fluid-Dynamic-simulation is used. The simulation results are proceeded
    to optimise the airflow and the arrangement of the breather holes. An important
    problem is the validation of the simulated results with the reality. It was necessary
    to build a non-invasive measurement system for the continuous characterisation
    of condensated areas without affecting the material properties, the airflow and
    the light distribution inside the headlight.
author:
- first_name: Michael
  full_name: Gulsch, Michael
  last_name: Gulsch
- first_name: Carsten
  full_name: Unverzagt, Carsten
  last_name: Unverzagt
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
- first_name: Sascha
  full_name: Nolte, Sascha
  last_name: Nolte
citation:
  ama: 'Gulsch M, Unverzagt C, Henning B, Nolte S. Visualisation and Measurement of
    Condensed Water in Automobile Headlights. In: ; 2005:455-460.'
  apa: Gulsch, M., Unverzagt, C., Henning, B., &#38; Nolte, S. (2005). Visualisation
    and Measurement of Condensed Water in Automobile Headlights (pp. 455–460). Presented
    at the Sensor/Test 2005, Nürnberg.
  bibtex: '@inproceedings{Gulsch_Unverzagt_Henning_Nolte_2005, title={Visualisation
    and Measurement of Condensed Water in Automobile Headlights}, author={Gulsch,
    Michael and Unverzagt, Carsten and Henning, Bernd and Nolte, Sascha}, year={2005},
    pages={455–460} }'
  chicago: Gulsch, Michael, Carsten Unverzagt, Bernd Henning, and Sascha Nolte. “Visualisation
    and Measurement of Condensed Water in Automobile Headlights,” 455–60, 2005.
  ieee: M. Gulsch, C. Unverzagt, B. Henning, and S. Nolte, “Visualisation and Measurement
    of Condensed Water in Automobile Headlights,” presented at the Sensor/Test 2005,
    Nürnberg, 2005, pp. 455–460.
  mla: Gulsch, Michael, et al. <i>Visualisation and Measurement of Condensed Water
    in Automobile Headlights</i>. 2005, pp. 455–60.
  short: 'M. Gulsch, C. Unverzagt, B. Henning, S. Nolte, in: 2005, pp. 455–460.'
conference:
  end_date: 11.05.2005
  location: Nürnberg
  name: Sensor/Test 2005
  start_date: 09.05.2005
date_created: 2019-12-17T15:41:19Z
date_updated: 2022-01-06T06:52:21Z
department:
- _id: '49'
language:
- iso: eng
page: 455-460
status: public
title: Visualisation and Measurement of Condensed Water in Automobile Headlights
type: conference
user_id: '15911'
year: '2005'
...
---
_id: '15356'
author:
- first_name: Peter
  full_name: Handel, Peter
  last_name: Handel
- first_name: Adam
  full_name: Tournier, Adam
  last_name: Tournier
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: Handel P, Tournier A, Henning B. Quantum 1/f Effect in Resonant Biochemical
    Piezoelectric and MEMS Sensors. <i>IEEE Transactions on Ultrasonics, Ferroelectrics,
    and Frequency Control</i>. 2005;52(9):1461-1467.
  apa: Handel, P., Tournier, A., &#38; Henning, B. (2005). Quantum 1/f Effect in Resonant
    Biochemical Piezoelectric and MEMS Sensors. <i>IEEE Transactions on Ultrasonics,
    Ferroelectrics, and Frequency Control</i>, <i>52</i>(9), 1461–1467.
  bibtex: '@article{Handel_Tournier_Henning_2005, title={Quantum 1/f Effect in Resonant
    Biochemical Piezoelectric and MEMS Sensors}, volume={52}, number={9}, journal={IEEE
    Transactions on Ultrasonics, Ferroelectrics, and Frequency Control}, author={Handel,
    Peter and Tournier, Adam and Henning, Bernd}, year={2005}, pages={1461–1467} }'
  chicago: 'Handel, Peter, Adam Tournier, and Bernd Henning. “Quantum 1/f Effect in
    Resonant Biochemical Piezoelectric and MEMS Sensors.” <i>IEEE Transactions on
    Ultrasonics, Ferroelectrics, and Frequency Control</i> 52, no. 9 (2005): 1461–67.'
  ieee: P. Handel, A. Tournier, and B. Henning, “Quantum 1/f Effect in Resonant Biochemical
    Piezoelectric and MEMS Sensors,” <i>IEEE Transactions on Ultrasonics, Ferroelectrics,
    and Frequency Control</i>, vol. 52, no. 9, pp. 1461–1467, 2005.
  mla: Handel, Peter, et al. “Quantum 1/f Effect in Resonant Biochemical Piezoelectric
    and MEMS Sensors.” <i>IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency
    Control</i>, vol. 52, no. 9, 2005, pp. 1461–67.
  short: P. Handel, A. Tournier, B. Henning, IEEE Transactions on Ultrasonics, Ferroelectrics,
    and Frequency Control 52 (2005) 1461–1467.
date_created: 2019-12-17T15:44:02Z
date_updated: 2022-01-06T06:52:21Z
department:
- _id: '49'
intvolume: '        52'
issue: '9'
language:
- iso: eng
page: 1461-1467
publication: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
status: public
title: Quantum 1/f Effect in Resonant Biochemical Piezoelectric and MEMS Sensors
type: journal_article
user_id: '15911'
volume: 52
year: '2005'
...
---
_id: '15358'
abstract:
- lang: eng
  text: In the 1950's many investigations have been made in measuring the Young's
    and the shear modus of isotropic materials with acoustic waves. Therefore both
    the longitudinal and transversal sound velocities have been determined with only
    one specimen, that had to be large in comparison to the wavelength (Brown, Reynolds,
    Dunegan). Therewith the method was suited only for low absorbing materials. In
    the 1990's further developments led to mono mode rods to describe viscoelastic
    properties. Their diameters had to be very small for high frequencies, thus giving
    practical values up to 65 kHz (Benatar). This contribution is about a tubular
    multi mode specimen and its application for the simultaneous measurement of the
    abovementioned acoustic properties at high frequencies.
author:
- first_name: Jens
  full_name: Rautenberg, Jens
  last_name: Rautenberg
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: 'Rautenberg J, Henning B. Acoustic properties of highly attenuating isotropic
    media. In: ; 2005.'
  apa: Rautenberg, J., &#38; Henning, B. (2005). Acoustic properties of highly attenuating
    isotropic media. Presented at the 6th World Congress on Ultrasonics (WCU 2005),
    Beijing, China.
  bibtex: '@inproceedings{Rautenberg_Henning_2005, title={Acoustic properties of highly
    attenuating isotropic media}, author={Rautenberg, Jens and Henning, Bernd}, year={2005}
    }'
  chicago: Rautenberg, Jens, and Bernd Henning. “Acoustic Properties of Highly Attenuating
    Isotropic Media,” 2005.
  ieee: J. Rautenberg and B. Henning, “Acoustic properties of highly attenuating isotropic
    media,” presented at the 6th World Congress on Ultrasonics (WCU 2005), Beijing,
    China, 2005.
  mla: Rautenberg, Jens, and Bernd Henning. <i>Acoustic Properties of Highly Attenuating
    Isotropic Media</i>. 2005.
  short: 'J. Rautenberg, B. Henning, in: 2005.'
conference:
  end_date: 09.09.2005
  location: Beijing, China
  name: 6th World Congress on Ultrasonics (WCU 2005)
  start_date: 28.08.2005
date_created: 2019-12-17T15:45:54Z
date_updated: 2022-01-06T06:52:21Z
department:
- _id: '49'
language:
- iso: eng
status: public
title: Acoustic properties of highly attenuating isotropic media
type: conference
user_id: '15911'
year: '2005'
...
---
_id: '15359'
abstract:
- lang: eng
  text: "In den bekannten grundlegenden Ausf¨uhrungen zur Erzeugung hörbaren Schalls
    durch Eigendemodulation amplitudenmodulierten\r\nLeistungsultraschalls (siehe
    u.a. Westervelt, Berktay) wird von zwei räumlich übereinander\r\nliegenden Wellen
    unterschiedlicher Frequenz im nichtlinearen Medium ausgegangen, so dass neben
    ihren\r\nHarmonischen auch Summen- und Differenzfrequenzen entstehen. Die perfekte
    räumliche Ueberdeckung\r\nder Wellen im Freifeld kann mit herkömmlichen Schallwandlern
    allerdings nur unzul¨anglich erreicht werden.\r\nTrotzdem sind in der Vergangenheit
    einige so genannte parametrische Lautsprecher entwickelt worden. Um\r\nannähernd
    die erwähnten Voraussetzungen zu gewährleisten, sind gängige Systeme mit einem
    Durchmesser\r\nvon ca. 30 cm relativ groß. Dies soll auch dem angestrebten Sekundärschalldruck
    Rechnung tragen, der linear\r\nmit der effektiv abstrahlenden Fl¨ache wächst.
    Zum Aufbau dieser großen Flächen werden teilweise viele\r\nkleine Ultraschallwandler
    zu einem Array zusammengesetzt. Der hohe Preis einzelner Wandler aber auch\r\ndie
    notwendige Sortierung beispielsweise bezüglich ihrer Mittenfrequenz macht den
    Aufbau solcher Systeme\r\naufwändig. Erst am vollständig aufgebauten Array werden
    schließlich Frequenzgang und Richtcharakteristik\r\ndes Sekundärschalls ermittelt.
    Im Sinne kürzerer Entwicklungszeiten und -kosten wäre es wünschenswert,\r\nbereits
    vor dem Aufbau des Arrays allein durch Untersuchung des einzelnen Ultraschallwandlers
    eine Prognose\r\nüber die zu erwartenden Eigenschaften des Gesamtsystems vornehmen
    zu können. In diesem Beitrag\r\nwird ein Versuchsaufbau vorgestellt, der unter
    strenger Beachtung der anfangs erwähnten Voraussetzungen\r\ndie parametrische
    Schallerzeugung mit nur einem Ultraschallwandler kleiner Baugröße erlaubt. Die
    Frequenzg\r\nänge des Sekundärschalls von Einzelelement und Array werden bei entsprechender
    Distanz gegen¨ubergestellt.\r\nVorzüge des neuen Messaufbaus, beispielsweise die
    Möglichkeit zur Variation von Druck, Temperatur\r\noder Luftfeuchtigkeit, um atmosphärische
    Einflüsse auf die parametrische Schallerzeugung zu untersuchen,\r\nwerden skizziert"
author:
- first_name: Jens
  full_name: Rautenberg, Jens
  last_name: Rautenberg
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
citation:
  ama: 'Rautenberg J, Henning B. Charakterisierung einzelner Ultraschallwandler für
    den Aufbau eines mehrelementigen parametrischen Lautsprechers. In: Fastl H, Fruhmann
    M, eds. <i>Fortschritte Der Akustik - DAGA ’05</i>. Berlin: Deutsche Gesellsch.
    f. Akustik; 2005:491-492.'
  apa: 'Rautenberg, J., &#38; Henning, B. (2005). Charakterisierung einzelner Ultraschallwandler
    für den Aufbau eines mehrelementigen parametrischen Lautsprechers. In H. Fastl
    &#38; M. Fruhmann (Eds.), <i>Fortschritte der Akustik - DAGA ’05</i> (pp. 491–492).
    Berlin: Deutsche Gesellsch. f. Akustik.'
  bibtex: '@inproceedings{Rautenberg_Henning_2005, place={Berlin}, title={Charakterisierung
    einzelner Ultraschallwandler für den Aufbau eines mehrelementigen parametrischen
    Lautsprechers}, booktitle={Fortschritte der Akustik - DAGA ’05}, publisher={Deutsche
    Gesellsch. f. Akustik}, author={Rautenberg, Jens and Henning, Bernd}, editor={Fastl,
    Hugo and Fruhmann, MarkusEditors}, year={2005}, pages={491–492} }'
  chicago: 'Rautenberg, Jens, and Bernd Henning. “Charakterisierung Einzelner Ultraschallwandler
    Für Den Aufbau Eines Mehrelementigen Parametrischen Lautsprechers.” In <i>Fortschritte
    Der Akustik - DAGA ’05</i>, edited by Hugo Fastl and Markus Fruhmann, 491–92.
    Berlin: Deutsche Gesellsch. f. Akustik, 2005.'
  ieee: J. Rautenberg and B. Henning, “Charakterisierung einzelner Ultraschallwandler
    für den Aufbau eines mehrelementigen parametrischen Lautsprechers,” in <i>Fortschritte
    der Akustik - DAGA ’05</i>, 2005, pp. 491–492.
  mla: Rautenberg, Jens, and Bernd Henning. “Charakterisierung Einzelner Ultraschallwandler
    Für Den Aufbau Eines Mehrelementigen Parametrischen Lautsprechers.” <i>Fortschritte
    Der Akustik - DAGA ’05</i>, edited by Hugo Fastl and Markus Fruhmann, Deutsche
    Gesellsch. f. Akustik, 2005, pp. 491–92.
  short: 'J. Rautenberg, B. Henning, in: H. Fastl, M. Fruhmann (Eds.), Fortschritte
    Der Akustik - DAGA ’05, Deutsche Gesellsch. f. Akustik, Berlin, 2005, pp. 491–492.'
date_created: 2019-12-17T15:46:48Z
date_updated: 2022-01-06T06:52:21Z
department:
- _id: '49'
editor:
- first_name: Hugo
  full_name: Fastl, Hugo
  last_name: Fastl
- first_name: Markus
  full_name: Fruhmann, Markus
  last_name: Fruhmann
language:
- iso: eng
page: 491-492
place: Berlin
publication: Fortschritte der Akustik - DAGA '05
publication_identifier:
  isbn:
  - 3-9808659-1-6
publisher: Deutsche Gesellsch. f. Akustik
status: public
title: Charakterisierung einzelner Ultraschallwandler für den Aufbau eines mehrelementigen
  parametrischen Lautsprechers
type: conference
user_id: '15911'
year: '2005'
...