[{"user_id":"34289","_id":"34176","publisher":"IEEE","language":[{"iso":"eng"}],"main_file_link":[{"url":"https://ieeexplore.ieee.org/abstract/document/9907278"}],"date_updated":"2023-10-23T09:04:23Z","publication_status":"published","conference":{"location":"Hanover, Germany","start_date":"2022-09-05","name":"24th European Conference on Power Electronics and Applications (EPE'22 ECCE Europe)","end_date":"2022-09-09"},"publication_identifier":{"isbn":["978-9-0758-1539-9"]},"author":[{"id":"34289","full_name":"Unruh, Roland","last_name":"Unruh","first_name":"Roland"},{"last_name":"Schafmeister","first_name":"Frank","full_name":"Schafmeister, Frank","id":"71291"},{"full_name":"Böcker, Joachim","last_name":"Böcker","first_name":"Joachim","orcid":"0000-0002-8480-7295","id":"66"}],"year":"2022","title":"Zero-Sequence Voltage Reduces DC-Link Capacitor Demand in Cascaded H-Bridge Converters for Large-Scale Electrolyzers by 40%","status":"public","department":[{"_id":"52"}],"keyword":["Cascaded H-Bridge","Solid-State Transformer","Zero sequence voltage","Third harmonic injection","Capacitor voltage ripple"],"type":"conference","date_created":"2022-12-02T12:47:38Z","abstract":[{"text":"Cascaded H-bridge Converters (CHBs) are a promising solution in converting power from a three-phase medium voltage of 6.6 kV...30 kV to a lower DC-voltage in the range of 100 V...1 kV to provide pure DC power to applications such as electrolyzers for hydrogen generation, data centers with a DC power distribution and DC microgrids. CHBs can be interpreted as modular multilevel converters with an isolated DC-DC output stage per module, require a large DC-link capacitor for each module to handle the second harmonic voltage ripple caused by the fluctuating input power within a fundamental grid period. Without a zero-sequence voltage injection, star-connected CHBs are operated with approximately sinusoidal arm voltages and currents. The floating star point potential enables to utilize different zero-sequence voltage injection techniques such as a third-harmonic injection with 1/6 of the grid voltage amplitude or a Min-Max voltage injection. Both well-known methods have the advantage to reduce the peak arm voltage and thereby the number of required modules by 13.4 % (to √ 3 2). This paper proves analytically that the third-harmonic injection with 1/6 of the grid voltage amplitude reduces the second harmonic voltage ripple by only 15.1 % compared to no-voltage injection for unity power factor operation and balanced grid voltages. Then it is shown, that the Min-Max injection has the often overlooked advantage of reducing the second harmonic voltage ripple by even 18.8 %. By applying the here proposed zero-sequence voltage injection in saturation modulation, the second harmonic voltage ripple of the DC-link capacitors is reduced by even 24.3 %, while still requiring the same number of modules as the Min-Max injection. For a realistic number of reserve modules, the overall energy ripple in the DC-link capacitors is reduced by 40 %.","lang":"eng"}],"citation":{"mla":"Unruh, Roland, et al. “Zero-Sequence Voltage Reduces DC-Link Capacitor Demand in Cascaded H-Bridge Converters for Large-Scale Electrolyzers by 40%.” <i>24th European Conference on Power Electronics and Applications (EPE’22 ECCE Europe)</i>, IEEE, 2022.","ama":"Unruh R, Schafmeister F, Böcker J. Zero-Sequence Voltage Reduces DC-Link Capacitor Demand in Cascaded H-Bridge Converters for Large-Scale Electrolyzers by 40%. In: <i>24th European Conference on Power Electronics and Applications (EPE’22 ECCE Europe)</i>. IEEE; 2022.","bibtex":"@inproceedings{Unruh_Schafmeister_Böcker_2022, title={Zero-Sequence Voltage Reduces DC-Link Capacitor Demand in Cascaded H-Bridge Converters for Large-Scale Electrolyzers by 40%}, booktitle={24th European Conference on Power Electronics and Applications (EPE’22 ECCE Europe)}, publisher={IEEE}, author={Unruh, Roland and Schafmeister, Frank and Böcker, Joachim}, year={2022} }","apa":"Unruh, R., Schafmeister, F., &#38; Böcker, J. (2022). Zero-Sequence Voltage Reduces DC-Link Capacitor Demand in Cascaded H-Bridge Converters for Large-Scale Electrolyzers by 40%. <i>24th European Conference on Power Electronics and Applications (EPE’22 ECCE Europe)</i>. 24th European Conference on Power Electronics and Applications (EPE’22 ECCE Europe), Hanover, Germany.","ieee":"R. Unruh, F. Schafmeister, and J. Böcker, “Zero-Sequence Voltage Reduces DC-Link Capacitor Demand in Cascaded H-Bridge Converters for Large-Scale Electrolyzers by 40%,” presented at the 24th European Conference on Power Electronics and Applications (EPE’22 ECCE Europe), Hanover, Germany, 2022.","short":"R. Unruh, F. Schafmeister, J. Böcker, in: 24th European Conference on Power Electronics and Applications (EPE’22 ECCE Europe), IEEE, 2022.","chicago":"Unruh, Roland, Frank Schafmeister, and Joachim Böcker. “Zero-Sequence Voltage Reduces DC-Link Capacitor Demand in Cascaded H-Bridge Converters for Large-Scale Electrolyzers by 40%.” In <i>24th European Conference on Power Electronics and Applications (EPE’22 ECCE Europe)</i>. IEEE, 2022."},"publication":"24th European Conference on Power Electronics and Applications (EPE'22 ECCE Europe)"}]