res:
  bibo_abstract:
  - In many different ultrasound applications mirrors are often used to deflect ultrasonic
    waves. The dimensions of the mirror and the applied materials have an essential
    influence on the output signal characteristics and the obtained measuring quantities.
    The extension of mirror geometry is not necessarily associated with a higher reflection
    coefficient. This can be explained with the aid of coincidence condition. A second
    criterion aims at the avoidance of the mirror resonance. This two conditions lead
    to an optimal dimensioning of mirror geometry with given material properties and
    operation mode, as exemplified for a rectangular mirror.@eng
  bibo_authorlist:
  - foaf_Person:
      foaf_givenName: Carsten
      foaf_name: Unverzagt, Carsten
      foaf_surname: Unverzagt
  - foaf_Person:
      foaf_givenName: Jens
      foaf_name: Rautenberg, Jens
      foaf_surname: Rautenberg
  - foaf_Person:
      foaf_givenName: Romina
      foaf_name: Kehl, Romina
      foaf_surname: Kehl
  - foaf_Person:
      foaf_givenName: Bernd
      foaf_name: Henning, Bernd
      foaf_surname: Henning
      foaf_workInfoHomepage: http://www.librecat.org/personId=213
  dct_date: 2006^xs_gYear
  dct_language: eng
  dct_title: Optimization of ultrasound reflecting mirrors@
...