_id: '15389'
abstract:
- lang: eng
  text: Recently there has been increased demand for chemicaJ sensors measuring in-line
    the concentration of selected substances in complex liquids in order to guarantee
    a high product quality in the process industry. At present there is a great interest
    in acoustic sensor systems for concentration measurements. This article presents
    a new ultrasonic sensor system consisting of a miniaturized multi-sensor arrangement
    for the comprehensive acoustic characterization of liquid mixtures. The sensor
    system measures sound velocity, impedance coefficient, attenuation coefficient
    an9 temperature.
author:
- first_name: Bernd
  full_name: Henning, Bernd
  id: '213'
  last_name: Henning
- first_name: Peter-Christoph
  full_name: Daur, Peter-Christoph
  last_name: Daur
- first_name: Stefan
  full_name: Prange, Stefan
  last_name: Prange
- first_name: Karsten
  full_name: Dierks, Karsten
  last_name: Dierks
- first_name: Peter
  full_name: Hauptmann, Peter
  last_name: Hauptmann
citation:
  ama: Henning B, Daur P-C, Prange S, Dierks K, Hauptmann P. In-line concentration
    measurement in complex liquids using ultrasonic sensors. <i>Ultrasonics</i>. 2000:799-803.
    doi:<a href="https://doi.org/10.1016/s0041-624x(99)00190-0">10.1016/s0041-624x(99)00190-0</a>
  apa: Henning, B., Daur, P.-C., Prange, S., Dierks, K., &#38; Hauptmann, P. (2000).
    In-line concentration measurement in complex liquids using ultrasonic sensors.
    <i>Ultrasonics</i>, 799–803. <a href="https://doi.org/10.1016/s0041-624x(99)00190-0">https://doi.org/10.1016/s0041-624x(99)00190-0</a>
  bibtex: '@article{Henning_Daur_Prange_Dierks_Hauptmann_2000, title={In-line concentration
    measurement in complex liquids using ultrasonic sensors}, DOI={<a href="https://doi.org/10.1016/s0041-624x(99)00190-0">10.1016/s0041-624x(99)00190-0</a>},
    journal={Ultrasonics}, author={Henning, Bernd and Daur, Peter-Christoph and Prange,
    Stefan and Dierks, Karsten and Hauptmann, Peter}, year={2000}, pages={799–803}
    }'
  chicago: Henning, Bernd, Peter-Christoph Daur, Stefan Prange, Karsten Dierks, and
    Peter Hauptmann. “In-Line Concentration Measurement in Complex Liquids Using Ultrasonic
    Sensors.” <i>Ultrasonics</i>, 2000, 799–803. <a href="https://doi.org/10.1016/s0041-624x(99)00190-0">https://doi.org/10.1016/s0041-624x(99)00190-0</a>.
  ieee: B. Henning, P.-C. Daur, S. Prange, K. Dierks, and P. Hauptmann, “In-line concentration
    measurement in complex liquids using ultrasonic sensors,” <i>Ultrasonics</i>,
    pp. 799–803, 2000.
  mla: Henning, Bernd, et al. “In-Line Concentration Measurement in Complex Liquids
    Using Ultrasonic Sensors.” <i>Ultrasonics</i>, 2000, pp. 799–803, doi:<a href="https://doi.org/10.1016/s0041-624x(99)00190-0">10.1016/s0041-624x(99)00190-0</a>.
  short: B. Henning, P.-C. Daur, S. Prange, K. Dierks, P. Hauptmann, Ultrasonics (2000)
    799–803.
date_created: 2019-12-18T15:01:18Z
date_updated: 2022-01-06T06:52:22Z
department:
- _id: '49'
doi: 10.1016/s0041-624x(99)00190-0
language:
- iso: eng
page: 799-803
publication: Ultrasonics
status: public
title: In-line concentration measurement in complex liquids using ultrasonic sensors
type: journal_article
user_id: '15911'
year: '2000'
...