<?xml version="1.0" encoding="UTF-8"?>
<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
         xmlns:dc="http://purl.org/dc/terms/"
         xmlns:foaf="http://xmlns.com/foaf/0.1/"
         xmlns:bibo="http://purl.org/ontology/bibo/"
         xmlns:fabio="http://purl.org/spar/fabio/"
         xmlns:owl="http://www.w3.org/2002/07/owl#"
         xmlns:event="http://purl.org/NET/c4dm/event.owl#"
         xmlns:ore="http://www.openarchives.org/ore/terms/">

    <rdf:Description rdf:about="https://ris.uni-paderborn.de/record/29849">
        <ore:isDescribedBy rdf:resource="https://ris.uni-paderborn.de/record/29849"/>
        <dc:title>Common-Mode-Free Bidirectional Three-Phase PFC-Rectifier for Non-Isolated EV Charger</dc:title>
        <bibo:authorList rdf:parseType="Collection">
            <foaf:Person>
                <foaf:name></foaf:name>
                <foaf:surname></foaf:surname>
                <foaf:givenname></foaf:givenname>
            </foaf:Person>
            <foaf:Person>
                <foaf:name></foaf:name>
                <foaf:surname></foaf:surname>
                <foaf:givenname></foaf:givenname>
            </foaf:Person>
            <foaf:Person>
                <foaf:name></foaf:name>
                <foaf:surname></foaf:surname>
                <foaf:givenname></foaf:givenname>
            </foaf:Person>
        </bibo:authorList>
        <bibo:abstract>DC-DC converters for on-board chargers (OBC) of electrical vehicles are usually galvanically isolated allowing modular single-phase PFC front-end solutions, but require transformers which are more bulky, costly and lossy than inductors of non-isolated DC-DCs. Furthermore, for vehicle-to-grid applications, bidirectional converters with transformers are generally more complex and have a higher count on semiconductor switches than transformerless solutions. However, when using non-isolated DC-DC converters within an OBC, the large common-mode (CM) capacitance comprising capacitive parasitics of the traction battery as well as explicit Y-capacitors connecting the high-voltage DC-system (HV-system) within specific HV-loads to ground has to be considered. For the PFC front-end stage, when supplied from the three-phase mains this means that generation of high-frequency and high-amplitude CM voltages, as it is common e.g. with the conventional six-switch full-bridge converter, has to be strictly avoided. For this reason, a modified topology is suggested leading to a different mode of operation and to a very low common-mode noise behaviour: The three-phase four-wire full-bridge PFC with split DC-link, whose midpoint is connected to the mains neutral provides very stable potentials at the DC-link rails and therefore it can be classified as Zero-CM-topology.For dedicated single-phase operation, as required for most OBC, an additional balancing leg may be added to the topology to reduce the required DC-link capacitance and allow non-electrolytic capacitors.The function of the bidirectional Zero-CM three-phase four-wire full-bridge PFC was verified by simulation and on an 11 kW-laboratory sample. The power factor is above 0.999 and an efficiency of 98 % is measured.</bibo:abstract>
        <dc:publisher>IEEE</dc:publisher>
        <bibo:doi rdf:resource="10.1109/apec42165.2021.9487462" />
        <ore:similarTo rdf:resource="info:doi/10.1109/apec42165.2021.9487462"/>
    </rdf:Description>
</rdf:RDF>