_id: '30661'
abstract:
- lang: eng
  text: As lightweight design gains more and more attention, time and cost-efficient
    joining methods such as clinching are becoming more popular. A clinch point’s
    quality is usually determined by ex situ destructive analyses such as microsectioning.
    However, these methods do not yield the detection of phenomena occurring during
    loading such as elastic deformations and cracks that close after unloading. Alternatively,
    in situ computed tomography (in situ CT) can be used to investigate the loading
    process of clinch points. In this paper, a method for in situ CT analysis of a
    single-lap shear test with clinched metal sheets is presented at the example of
    a clinched joint with two 2 mm thick aluminum sheets. Furthermore, the potential
    of this method to validate numerical simulations is shown. Since the sheets’ surfaces
    are locally in contact with each other, the interface between both aluminum sheets
    and therefore the exact contour of the joining partners is difficult to identify
    in CT analyses. To compensate for this, the application of copper varnish between
    the sheets is investigated. The best in situ CT results are achieved with both
    sheets treated. It showed that with this treatment, in situ CT is suitable to
    properly observe the three-dimensional deformation behavior and to identify the
    failure modes.
author:
- first_name: D.
  full_name: Köhler, D.
  last_name: Köhler
- first_name: R.
  full_name: Kupfer, R.
  last_name: Kupfer
- first_name: J.
  full_name: Troschitz, J.
  last_name: Troschitz
- first_name: M.
  full_name: Gude, M.
  last_name: Gude
citation:
  ama: Köhler D, Kupfer R, Troschitz J, Gude M. In Situ Computed Tomography—Analysis
    of a Single-Lap Shear Test with Clinch Points. <i>Materials</i>. 2021;14:1859.
    doi:<a href="https://doi.org/10.3390/ma14081859">10.3390/ma14081859</a>
  apa: Köhler, D., Kupfer, R., Troschitz, J., &#38; Gude, M. (2021). In Situ Computed
    Tomography—Analysis of a Single-Lap Shear Test with Clinch Points. <i>Materials</i>,
    <i>14</i>, 1859. <a href="https://doi.org/10.3390/ma14081859">https://doi.org/10.3390/ma14081859</a>
  bibtex: '@article{Köhler_Kupfer_Troschitz_Gude_2021, title={In Situ Computed Tomography—Analysis
    of a Single-Lap Shear Test with Clinch Points}, volume={14}, DOI={<a href="https://doi.org/10.3390/ma14081859">10.3390/ma14081859</a>},
    journal={Materials}, author={Köhler, D. and Kupfer, R. and Troschitz, J. and Gude,
    M.}, year={2021}, pages={1859} }'
  chicago: 'Köhler, D., R. Kupfer, J. Troschitz, and M. Gude. “In Situ Computed Tomography—Analysis
    of a Single-Lap Shear Test with Clinch Points.” <i>Materials</i> 14 (2021): 1859.
    <a href="https://doi.org/10.3390/ma14081859">https://doi.org/10.3390/ma14081859</a>.'
  ieee: 'D. Köhler, R. Kupfer, J. Troschitz, and M. Gude, “In Situ Computed Tomography—Analysis
    of a Single-Lap Shear Test with Clinch Points,” <i>Materials</i>, vol. 14, p.
    1859, 2021, doi: <a href="https://doi.org/10.3390/ma14081859">10.3390/ma14081859</a>.'
  mla: Köhler, D., et al. “In Situ Computed Tomography—Analysis of a Single-Lap Shear
    Test with Clinch Points.” <i>Materials</i>, vol. 14, 2021, p. 1859, doi:<a href="https://doi.org/10.3390/ma14081859">10.3390/ma14081859</a>.
  short: D. Köhler, R. Kupfer, J. Troschitz, M. Gude, Materials 14 (2021) 1859.
date_created: 2022-03-28T13:41:29Z
date_updated: 2022-03-30T07:53:37Z
doi: 10.3390/ma14081859
intvolume: '        14'
language:
- iso: eng
page: '1859'
project:
- _id: '130'
  grant_number: '418701707'
  name: 'TRR 285: TRR 285'
- _id: '133'
  name: 'TRR 285 - C: TRR 285 - Project Area C'
- _id: '148'
  name: 'TRR 285 – C04: TRR 285 - Subproject C04'
publication: Materials
status: public
title: In Situ Computed Tomography—Analysis of a Single-Lap Shear Test with Clinch
  Points
type: journal_article
user_id: '68518'
volume: 14
year: '2021'
...