{"user_id":"107107","publisher":"Walter de Gruyter GmbH","publication":"tm - Technisches Messen","issue":"s1","page":"2-7","year":"2024","citation":{"bibtex":"@article{Butzhammer_Hausotte_2024, title={Task-specific scan trajectory modification for dimensional X-ray computed Tomography with high throughput}, volume={91}, DOI={10.1515/teme-2024-0044}, number={s1}, journal={tm - Technisches Messen}, publisher={Walter de Gruyter GmbH}, author={Butzhammer, Lorenz and Hausotte, Tino}, year={2024}, pages={2–7} }","mla":"Butzhammer, Lorenz, and Tino Hausotte. “Task-Specific Scan Trajectory Modification for Dimensional X-Ray Computed Tomography with High Throughput.” Tm - Technisches Messen, vol. 91, no. s1, Walter de Gruyter GmbH, 2024, pp. 2–7, doi:10.1515/teme-2024-0044.","ieee":"L. Butzhammer and T. Hausotte, “Task-specific scan trajectory modification for dimensional X-ray computed Tomography with high throughput,” tm - Technisches Messen, vol. 91, no. s1, pp. 2–7, 2024, doi: 10.1515/teme-2024-0044.","apa":"Butzhammer, L., & Hausotte, T. (2024). Task-specific scan trajectory modification for dimensional X-ray computed Tomography with high throughput. Tm - Technisches Messen, 91(s1), 2–7. https://doi.org/10.1515/teme-2024-0044","chicago":"Butzhammer, Lorenz, and Tino Hausotte. “Task-Specific Scan Trajectory Modification for Dimensional X-Ray Computed Tomography with High Throughput.” Tm - Technisches Messen 91, no. s1 (2024): 2–7. https://doi.org/10.1515/teme-2024-0044.","short":"L. Butzhammer, T. Hausotte, Tm - Technisches Messen 91 (2024) 2–7.","ama":"Butzhammer L, Hausotte T. Task-specific scan trajectory modification for dimensional X-ray computed Tomography with high throughput. tm - Technisches Messen. 2024;91(s1):2-7. doi:10.1515/teme-2024-0044"},"title":"Task-specific scan trajectory modification for dimensional X-ray computed Tomography with high throughput","_id":"61779","type":"journal_article","volume":91,"publication_identifier":{"issn":["2196-7113","0171-8096"]},"date_created":"2025-10-10T16:56:13Z","intvolume":" 91","date_updated":"2025-10-11T08:02:46Z","language":[{"iso":"eng"}],"abstract":[{"text":"Zusammenfassung\r\n Eine Erweiterung der Scantrajektorie für die industrielle Röntgen-Computertomographie von einer kreisförmigen Form (entsprechend einer 360°-Rotation des Messobjekts) hin zu frei wählbaren Aufnahmeposen hat das Potenzial, durch eine geeignete Trajektorienanpassung Messabweichungen zu reduzieren. In diesem Beitrag wird eine solche Trajektorienanpassung durch einen Hexapoden als Messobjektmanipulator und eine güteparameterbasierte Methodik zur Wahl einzelner Trajektorienpunkte erreicht. Die Ergebnisse zeigen, dass sich vor allem für eine geringe Projektionszahl signifikante Vorteile ergeben, was vor allem im Hinblick auf Inline-CT mit hohem Durchsatz von Relevanz ist.","lang":"eng"}],"publication_status":"published","doi":"10.1515/teme-2024-0044","status":"public","author":[{"last_name":"Butzhammer","full_name":"Butzhammer, Lorenz","first_name":"Lorenz"},{"full_name":"Hausotte, Tino","last_name":"Hausotte","first_name":"Tino"}]}