res:
  bibo_abstract:
  - "<jats:p>\r\n                    The development of practical sensors for optical
    coherence tomography (OCT) with undetected photons requires miniaturization via
    integration. To be practical, these sensors must exhibit a large spectral bandwidth
    and a high brightness, which are linked to a high axial resolution and a sufficient
    signal-to-noise ratio, respectively. Here, we combine these requirements in a
    scheme for OCT measurements with undetected photons based on nonlinear\r\n                    <a:math
    xmlns:a=\"http://www.w3.org/1998/Math/MathML\" display=\"inline\">\r\n                      <a:mi>Ti</a:mi>\r\n
    \                     <a:mo>:</a:mo>\r\n                      <a:msub>\r\n                        <a:mrow>\r\n
    \                         <a:mi>Li</a:mi>\r\n                          <a:mi>Nb</a:mi>\r\n
    \                         <a:mi mathvariant=\"normal\">O</a:mi>\r\n                        </a:mrow>\r\n
    \                       <a:mn>3</a:mn>\r\n                      </a:msub>\r\n
    \                   </a:math>\r\n                    waveguides. We investigate
    the performance benchmarks of the commonly used SU(1,1) scheme in comparison to
    an induced-coherence scheme and find that the latter is actually better suited
    when implementing measurements with undetected photons in integrated systems.
    In both schemes, we perform pump-gain optimization and OCT measurements with undetected
    photons with an axial resolution as low as\r\n                    <d:math xmlns:d=\"http://www.w3.org/1998/Math/MathML\"
    display=\"inline\">\r\n                      <d:mn>28</d:mn>\r\n                      <d:mspace
    width=\"0.2em\"/>\r\n                      <d:mtext fontfamily=\"times\">μ</d:mtext>\r\n
    \                     <d:mrow>\r\n                        <d:mi mathvariant=\"normal\">m</d:mi>\r\n
    \                     </d:mrow>\r\n                    </d:math>\r\n                    .\r\n
    \                 </jats:p>@eng"
  bibo_authorlist:
  - foaf_Person:
      foaf_givenName: Franz
      foaf_name: Roeder, Franz
      foaf_surname: Roeder
      foaf_workInfoHomepage: http://www.librecat.org/personId=88149
  - foaf_Person:
      foaf_givenName: René
      foaf_name: Pollmann, René
      foaf_surname: Pollmann
      foaf_workInfoHomepage: http://www.librecat.org/personId=78890
  - foaf_Person:
      foaf_givenName: Viktor
      foaf_name: Quiring, Viktor
      foaf_surname: Quiring
  - foaf_Person:
      foaf_givenName: Christof
      foaf_name: Eigner, Christof
      foaf_surname: Eigner
      foaf_workInfoHomepage: http://www.librecat.org/personId=13244
    orcid: https://orcid.org/0000-0002-5693-3083
  - foaf_Person:
      foaf_givenName: Benjamin
      foaf_name: Brecht, Benjamin
      foaf_surname: Brecht
      foaf_workInfoHomepage: http://www.librecat.org/personId=27150
    orcid: '0000-0003-4140-0556 '
  - foaf_Person:
      foaf_givenName: Christine
      foaf_name: Silberhorn, Christine
      foaf_surname: Silberhorn
      foaf_workInfoHomepage: http://www.librecat.org/personId=26263
  bibo_doi: 10.1103/cwsx-42c4
  bibo_issue: '3'
  bibo_volume: 25
  dct_date: 2026^xs_gYear
  dct_isPartOf:
  - http://id.crossref.org/issn/2331-7019
  dct_language: eng
  dct_publisher: American Physical Society (APS)@
  dct_title: Toward integrated sensors for optimized optical coherence tomography
    with undetected photons@
...