<?xml version="1.0" encoding="UTF-8"?>
<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
         xmlns:dc="http://purl.org/dc/terms/"
         xmlns:foaf="http://xmlns.com/foaf/0.1/"
         xmlns:bibo="http://purl.org/ontology/bibo/"
         xmlns:fabio="http://purl.org/spar/fabio/"
         xmlns:owl="http://www.w3.org/2002/07/owl#"
         xmlns:event="http://purl.org/NET/c4dm/event.owl#"
         xmlns:ore="http://www.openarchives.org/ore/terms/">

    <rdf:Description rdf:about="https://ris.uni-paderborn.de/record/65577">
        <ore:isDescribedBy rdf:resource="https://ris.uni-paderborn.de/record/65577"/>
        <dc:title>In-situ CT of Viscoelastic Plastic Materials: A Radiography-Based Lead Time Determination for Composite–Metal Joints at Elevated Temperature</dc:title>
        <bibo:authorList rdf:parseType="Collection">
            <foaf:Person>
                <foaf:name></foaf:name>
                <foaf:surname></foaf:surname>
                <foaf:givenname></foaf:givenname>
            </foaf:Person>
            <foaf:Person>
                <foaf:name></foaf:name>
                <foaf:surname></foaf:surname>
                <foaf:givenname></foaf:givenname>
            </foaf:Person>
            <foaf:Person>
                <foaf:name></foaf:name>
                <foaf:surname></foaf:surname>
                <foaf:givenname></foaf:givenname>
            </foaf:Person>
            <foaf:Person>
                <foaf:name></foaf:name>
                <foaf:surname></foaf:surname>
                <foaf:givenname></foaf:givenname>
            </foaf:Person>
        </bibo:authorList>
        <bibo:abstract>&lt;jats:p&gt;In-situ computed tomography (CT) experiments on materials with time-dependent mechanical behaviour are affected by relaxationinduced motion, which can lead to image blur and motion-related artefacts if scans are initiated before relaxation-induced motion has subsided. Scan start times are therefore commonly defined based on force relaxation or force-gradient criteria, although these signals do not directly quantify image-relevant specimen motion. In this work, a radiography-based approach is presented to estimate relaxation-induced motion via pixel shifts from projection images acquired prior to CT scans. These projection-based pixel shift estimates of relaxation-induced motion are related to scan-specific image blur observed in the reconstructed volumes. Thereby, a direct link between specimen motion during the scan and CT image quality is established. The method is demonstrated for thermo-mechanically loaded specimens with pronounced temperature-dependent material behaviour, where relaxation-induced motion persists over extended time scales. The results show that projection-based pixel shift estimation provides a physically meaningful and experimentally accessible basis for defining scan start criteria. CT acquisition can be initiated based on an allowable level of relaxation-induced motion, rather than waiting for mechanical equilibrium to be reached. The proposed approach therefore offers a direct, image-related framework for scan timing in in-situ CT experiments on time-dependent materials.&lt;/jats:p&gt;</bibo:abstract>
        <bibo:volume>31</bibo:volume>
        <bibo:issue>3</bibo:issue>
        <dc:publisher>NDT.net GmbH &amp; Co. KG</dc:publisher>
        <bibo:doi rdf:resource="10.58286/32601" />
        <ore:similarTo rdf:resource="info:doi/10.58286/32601"/>
    </rdf:Description>
</rdf:RDF>