<?xml version="1.0" encoding="UTF-8"?>

<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3">

<genre>conference paper</genre>

<titleInfo><title>A simple pre-stress estimating method of langevin transducers</title></titleInfo>





<name type="personal">
  <namePart type="given">Fu</namePart>
  <namePart type="family">Bo</namePart>
  <role><roleTerm type="text">author</roleTerm> </role></name>
<name type="personal">
  <namePart type="given">Li</namePart>
  <namePart type="family">Ting</namePart>
  <role><roleTerm type="text">author</roleTerm> </role></name>
<name type="personal">
  <namePart type="given">Tobias</namePart>
  <namePart type="family">Hemsel</namePart>
  <role><roleTerm type="text">author</roleTerm> </role><identifier type="local">210</identifier></name>







<name type="corporate">
  <namePart></namePart>
  <identifier type="local">151</identifier>
  <role>
    <roleTerm type="text">department</roleTerm>
  </role>
</name>








<abstract lang="eng">A simple pre-stress estimate method of Langevin transducers is studied. The measurement setup consists of a capacitor, an impedance converter and a voltmeter. Based on the piezoelectric equation and the basic circuit theory, the mathematical expression between the pre-stress and the voltage across the capacitor is derived. The pre-stress level can then be calculated out of the measurement of the capacitor voltage. In order to evaluate the precision of this method, a force washer is used to measure the pre-stress of the Langevin transducer. The result shows the pre-stress level obtained from this method is 30-40\% higher than the pre-stress level measured by the force washer. This method is simple and can be used to estimate the pre-stress of various Langevin transducers. The precision of this method can be raised if d33 is identified under different pre-stress levels.</abstract>

<originInfo><dateIssued encoding="w3cdtf">2008</dateIssued>
</originInfo>
<language><languageTerm authority="iso639-2b" type="code">eng</languageTerm>
</language>

<subject><topic>capacitors</topic><topic>impedance convertors</topic><topic>piezoelectric transducers</topic><topic>stress analysis</topic><topic>Langevin transducers</topic><topic>basic circuit theory</topic><topic>capacitor</topic><topic>impedance converter</topic><topic>piezoelectric equation</topic><topic>pre-stress estimating method</topic><topic>voltmeter</topic><topic>Capacitors</topic><topic>Educational institutions</topic><topic>Equations</topic><topic>Force measurement</topic><topic>Impedance measurement</topic><topic>Manufacturing</topic><topic>Mechatronics</topic><topic>Piezoelectric transducers</topic><topic>Voltage</topic><topic>Voltmeters</topic><topic>Langevin transducer</topic><topic>capacitor</topic><topic>piezoelectric element</topic><topic>pre-stress</topic>
</subject>


<relatedItem type="host"><titleInfo><title>Piezoelectricity, Acoustic Waves, and Device Applications, 2008. SPAWDA 2008. Symposium on</title></titleInfo><identifier type="doi">10.1109/SPAWDA.2008.4775801</identifier>
<part><extent unit="pages">324-327</extent>
</part>
</relatedItem>


<extension>
<bibliographicCitation>
<chicago>Bo, Fu, Li Ting, and Tobias Hemsel. “A Simple Pre-Stress Estimating Method of Langevin Transducers.” In &lt;i&gt;Piezoelectricity, Acoustic Waves, and Device Applications, 2008. SPAWDA 2008. Symposium On&lt;/i&gt;, 324–27, 2008. &lt;a href=&quot;https://doi.org/10.1109/SPAWDA.2008.4775801&quot;&gt;https://doi.org/10.1109/SPAWDA.2008.4775801&lt;/a&gt;.</chicago>
<ieee>F. Bo, L. Ting, and T. Hemsel, “A simple pre-stress estimating method of langevin transducers,” in &lt;i&gt;Piezoelectricity, Acoustic Waves, and Device Applications, 2008. SPAWDA 2008. Symposium on&lt;/i&gt;, 2008, pp. 324–327.</ieee>
<ama>Bo F, Ting L, Hemsel T. A simple pre-stress estimating method of langevin transducers. In: &lt;i&gt;Piezoelectricity, Acoustic Waves, and Device Applications, 2008. SPAWDA 2008. Symposium On&lt;/i&gt;. ; 2008:324-327. doi:&lt;a href=&quot;https://doi.org/10.1109/SPAWDA.2008.4775801&quot;&gt;10.1109/SPAWDA.2008.4775801&lt;/a&gt;</ama>
<short>F. Bo, L. Ting, T. Hemsel, in: Piezoelectricity, Acoustic Waves, and Device Applications, 2008. SPAWDA 2008. Symposium On, 2008, pp. 324–327.</short>
<bibtex>@inproceedings{Bo_Ting_Hemsel_2008, title={A simple pre-stress estimating method of langevin transducers}, DOI={&lt;a href=&quot;https://doi.org/10.1109/SPAWDA.2008.4775801&quot;&gt;10.1109/SPAWDA.2008.4775801&lt;/a&gt;}, booktitle={Piezoelectricity, Acoustic Waves, and Device Applications, 2008. SPAWDA 2008. Symposium on}, author={Bo, Fu and Ting, Li and Hemsel, Tobias}, year={2008}, pages={324–327} }</bibtex>
<mla>Bo, Fu, et al. “A Simple Pre-Stress Estimating Method of Langevin Transducers.” &lt;i&gt;Piezoelectricity, Acoustic Waves, and Device Applications, 2008. SPAWDA 2008. Symposium On&lt;/i&gt;, 2008, pp. 324–27, doi:&lt;a href=&quot;https://doi.org/10.1109/SPAWDA.2008.4775801&quot;&gt;10.1109/SPAWDA.2008.4775801&lt;/a&gt;.</mla>
<apa>Bo, F., Ting, L., &amp;#38; Hemsel, T. (2008). A simple pre-stress estimating method of langevin transducers. In &lt;i&gt;Piezoelectricity, Acoustic Waves, and Device Applications, 2008. SPAWDA 2008. Symposium on&lt;/i&gt; (pp. 324–327). &lt;a href=&quot;https://doi.org/10.1109/SPAWDA.2008.4775801&quot;&gt;https://doi.org/10.1109/SPAWDA.2008.4775801&lt;/a&gt;</apa>
</bibliographicCitation>
</extension>
<recordInfo><recordIdentifier>9568</recordIdentifier><recordCreationDate encoding="w3cdtf">2019-04-29T11:16:13Z</recordCreationDate><recordChangeDate encoding="w3cdtf">2022-01-06T07:04:16Z</recordChangeDate>
</recordInfo>
</mods>
</modsCollection>
