<?xml version="1.0" encoding="UTF-8"?>

<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3">

<genre>article</genre>

<titleInfo><title>Modeling of Piezoelectric Langevin Transducers by Using Mixed Transfer Matrix Methods</title></titleInfo>




<note type="qualityControlled">yes</note>

<name type="personal">
  <namePart type="given">Bo</namePart>
  <namePart type="family">Fu</namePart>
  <role><roleTerm type="text">author</roleTerm> </role></name>
<name type="personal">
  <namePart type="given">Chao</namePart>
  <namePart type="family">Li</namePart>
  <role><roleTerm type="text">author</roleTerm> </role></name>
<name type="personal">
  <namePart type="given">Jianming</namePart>
  <namePart type="family">Zhang</namePart>
  <role><roleTerm type="text">author</roleTerm> </role></name>
<name type="personal">
  <namePart type="given">Zhenwei</namePart>
  <namePart type="family">Huang</namePart>
  <role><roleTerm type="text">author</roleTerm> </role></name>
<name type="personal">
  <namePart type="given">Tobias</namePart>
  <namePart type="family">Hemsel</namePart>
  <role><roleTerm type="text">author</roleTerm> </role><identifier type="local">210</identifier></name>







<name type="corporate">
  <namePart></namePart>
  <identifier type="local">151</identifier>
  <role>
    <roleTerm type="text">department</roleTerm>
  </role>
</name>








<abstract lang="eng">In the modeling of piezoelectric Langevin transducers using usual transfer matrix methods, some simplifications have been adopted. This leads to reduction of the model quality. A mixed transfer matrix method is employed in the modeling of Langevin transducers, where the pre-stressed bolt is modeled as a separate four-pole element, which is connected to other elements in parallel. Based on the mixed transfer matrix method, the four (six)-pole element description of the piezoelectric Langevin transducer is built up and the total transfer matrix relation is derived. The resonance frequencies of the transducer are calculated and then measured using the impedance analyzer (HP4192). Experimental result shows that the mixed transfer matrix method has better modeling quality than the usual transfer matrix method for the vibration analysis of piezoelectric Langevin transducers.</abstract>

<originInfo><dateIssued encoding="w3cdtf">2010</dateIssued>
</originInfo>
<language><languageTerm authority="iso639-2b" type="code">eng</languageTerm>
</language>

<subject><topic>Piezoelectric langevin transducer</topic><topic>Transfer matrix method</topic><topic>Four (six)-pole element description</topic><topic>Pre-stressed bolt</topic>
</subject>


<relatedItem type="host"><titleInfo><title>Journal of Korean Physical Society</title></titleInfo>
  <identifier type="issn">1948-5719</identifier><identifier type="doi">10.3938/jkps.57.929</identifier>
<part><detail type="volume"><number>57</number></detail><detail type="issue"><number>4</number></detail><extent unit="pages">929</extent>
</part>
</relatedItem>


<extension>
<bibliographicCitation>
<apa>Fu, B., Li, C., Zhang, J., Huang, Z., &amp;#38; Hemsel, T. (2010). Modeling of Piezoelectric Langevin Transducers by Using Mixed Transfer Matrix Methods. &lt;i&gt;Journal of Korean Physical Society&lt;/i&gt;, &lt;i&gt;57&lt;/i&gt;(4), 929. &lt;a href=&quot;https://doi.org/10.3938/jkps.57.929&quot;&gt;https://doi.org/10.3938/jkps.57.929&lt;/a&gt;</apa>
<bibtex>@article{Fu_Li_Zhang_Huang_Hemsel_2010, title={Modeling of Piezoelectric Langevin Transducers by Using Mixed Transfer Matrix Methods}, volume={57}, DOI={&lt;a href=&quot;https://doi.org/10.3938/jkps.57.929&quot;&gt;10.3938/jkps.57.929&lt;/a&gt;}, number={4}, journal={Journal of Korean Physical Society}, author={Fu, Bo and Li, Chao and Zhang, Jianming and Huang, Zhenwei and Hemsel, Tobias}, year={2010}, pages={929} }</bibtex>
<mla>Fu, Bo, et al. “Modeling of Piezoelectric Langevin Transducers by Using Mixed Transfer Matrix Methods.” &lt;i&gt;Journal of Korean Physical Society&lt;/i&gt;, vol. 57, no. 4, 2010, p. 929, doi:&lt;a href=&quot;https://doi.org/10.3938/jkps.57.929&quot;&gt;10.3938/jkps.57.929&lt;/a&gt;.</mla>
<short>B. Fu, C. Li, J. Zhang, Z. Huang, T. Hemsel, Journal of Korean Physical Society 57 (2010) 929.</short>
<ieee>B. Fu, C. Li, J. Zhang, Z. Huang, and T. Hemsel, “Modeling of Piezoelectric Langevin Transducers by Using Mixed Transfer Matrix Methods,” &lt;i&gt;Journal of Korean Physical Society&lt;/i&gt;, vol. 57, no. 4, p. 929, 2010.</ieee>
<chicago>Fu, Bo, Chao Li, Jianming Zhang, Zhenwei Huang, and Tobias Hemsel. “Modeling of Piezoelectric Langevin Transducers by Using Mixed Transfer Matrix Methods.” &lt;i&gt;Journal of Korean Physical Society&lt;/i&gt; 57, no. 4 (2010): 929. &lt;a href=&quot;https://doi.org/10.3938/jkps.57.929&quot;&gt;https://doi.org/10.3938/jkps.57.929&lt;/a&gt;.</chicago>
<ama>Fu B, Li C, Zhang J, Huang Z, Hemsel T. Modeling of Piezoelectric Langevin Transducers by Using Mixed Transfer Matrix Methods. &lt;i&gt;Journal of Korean Physical Society&lt;/i&gt;. 2010;57(4):929. doi:&lt;a href=&quot;https://doi.org/10.3938/jkps.57.929&quot;&gt;10.3938/jkps.57.929&lt;/a&gt;</ama>
</bibliographicCitation>
</extension>
<recordInfo><recordIdentifier>9745</recordIdentifier><recordCreationDate encoding="w3cdtf">2019-05-13T09:40:42Z</recordCreationDate><recordChangeDate encoding="w3cdtf">2022-01-06T07:04:19Z</recordChangeDate>
</recordInfo>
</mods>
</modsCollection>
