In-situ CT of Viscoelastic Plastic Materials: A Radiography-Based Lead Time Determination for Composite–Metal Joints at Elevated Temperature
A. Dargel, J. Troschitz, M. Gude, R. Kupfer, E-Journal of Nondestructive Testing 31 (2026).
Download
ict26_Contribution_227.pdf
10.03 MB
DOI
Journal Article
| Published
| English
Author
Dargel, Alrik;
Troschitz, Juliane;
Gude, Maik;
Kupfer, Robert
Abstract
<jats:p>In-situ computed tomography (CT) experiments on materials with time-dependent mechanical behaviour are affected by relaxationinduced motion, which can lead to image blur and motion-related artefacts if scans are initiated before relaxation-induced motion has subsided. Scan start times are therefore commonly defined based on force relaxation or force-gradient criteria, although these signals do not directly quantify image-relevant specimen motion. In this work, a radiography-based approach is presented to estimate relaxation-induced motion via pixel shifts from projection images acquired prior to CT scans. These projection-based pixel shift estimates of relaxation-induced motion are related to scan-specific image blur observed in the reconstructed volumes. Thereby, a direct link between specimen motion during the scan and CT image quality is established. The method is demonstrated for thermo-mechanically loaded specimens with pronounced temperature-dependent material behaviour, where relaxation-induced motion persists over extended time scales. The results show that projection-based pixel shift estimation provides a physically meaningful and experimentally accessible basis for defining scan start criteria. CT acquisition can be initiated based on an allowable level of relaxation-induced motion, rather than waiting for mechanical equilibrium to be reached. The proposed approach therefore offers a direct, image-related framework for scan timing in in-situ CT experiments on time-dependent materials.</jats:p>
Publishing Year
Journal Title
e-Journal of Nondestructive Testing
Volume
31
Issue
3
ISSN
LibreCat-ID
Cite this
Dargel A, Troschitz J, Gude M, Kupfer R. In-situ CT of Viscoelastic Plastic Materials: A Radiography-Based Lead Time Determination for Composite–Metal Joints at Elevated Temperature. e-Journal of Nondestructive Testing. 2026;31(3). doi:10.58286/32601
Dargel, A., Troschitz, J., Gude, M., & Kupfer, R. (2026). In-situ CT of Viscoelastic Plastic Materials: A Radiography-Based Lead Time Determination for Composite–Metal Joints at Elevated Temperature. E-Journal of Nondestructive Testing, 31(3). https://doi.org/10.58286/32601
@article{Dargel_Troschitz_Gude_Kupfer_2026, title={In-situ CT of Viscoelastic Plastic Materials: A Radiography-Based Lead Time Determination for Composite–Metal Joints at Elevated Temperature}, volume={31}, DOI={10.58286/32601}, number={3}, journal={e-Journal of Nondestructive Testing}, publisher={NDT.net GmbH & Co. KG}, author={Dargel, Alrik and Troschitz, Juliane and Gude, Maik and Kupfer, Robert}, year={2026} }
Dargel, Alrik, Juliane Troschitz, Maik Gude, and Robert Kupfer. “In-Situ CT of Viscoelastic Plastic Materials: A Radiography-Based Lead Time Determination for Composite–Metal Joints at Elevated Temperature.” E-Journal of Nondestructive Testing 31, no. 3 (2026). https://doi.org/10.58286/32601.
A. Dargel, J. Troschitz, M. Gude, and R. Kupfer, “In-situ CT of Viscoelastic Plastic Materials: A Radiography-Based Lead Time Determination for Composite–Metal Joints at Elevated Temperature,” e-Journal of Nondestructive Testing, vol. 31, no. 3, 2026, doi: 10.58286/32601.
Dargel, Alrik, et al. “In-Situ CT of Viscoelastic Plastic Materials: A Radiography-Based Lead Time Determination for Composite–Metal Joints at Elevated Temperature.” E-Journal of Nondestructive Testing, vol. 31, no. 3, NDT.net GmbH & Co. KG, 2026, doi:10.58286/32601.
Main File(s)
File Name
ict26_Contribution_227.pdf
10.03 MB
Access Level
Closed Access
Last Uploaded
2026-03-06T10:20:14Z